Replacing Gas Stoves With Portable Electric Appliances to Improve Indoor Air Quality and Asthma Control
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Portable cooking appliances.
- Who it may be relevant to
- Registry conditions: Asthma Control. Basic parameters: from 18 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Center list to be confirmed — check the primary protocol.
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Overview
The goals of this study are to determine if replacing gas stoves with portable electric hot plates and electric toaster ovens will improve indoor air quality and asthma control. Researchers will enroll participants with poorly controlled asthma and provide them with hot plates and toaster ovens to use instead of gas stoves. Researchers will measure indoor air quality about 1-2 weeks before and about 2-3 months after providing portable appliances. Participants will answer questions about their asthma symptoms and take lung function tests about 1-2 weeks before and about 2-3 months after using portable appliances.
Detailed description
Cooking on natural gas stoves is a major source of indoor air pollution and may contribute to asthma exacerbations. The investigators recently completed a single-arm trial in which gas stoves were replaced with electric induction stoves in the homes of 85 individuals with poorly controlled asthma. This led to 70% reductions in indoor NO2 levels and clinically important improvements in multiple measures of asthma control. Asthma Control Questionnaire scores improved by 1.1 points in this trial, which is twice as large as the average improvement seen with medical treatment such as inhaled corticosteroids and/or long-acting beta-agonists.
While these results are promising, the trial lacked a control group which limits the causal inferences that can be drawn. In addition, lung function was not directly measured. Moreover, the costs for stove installation and required electrical upgrades averaged nearly $10,000 per home. Most of this cost was related to the older housing stock of trial participants that often required upgrading the entire electrical panel in a house to install a new 240-volt kitchen outlet for the new electric stove. These costs can be a financial challenge for low-income households, limiting the scalability of a potentially effective solution for improving indoor air quality and asthma control.
To address these limitations, the investigators now propose a pilot randomized controlled trial using a delayed crossover design to evaluate the effectiveness of a low-cost intervention to improve indoor air quality, asthma control, and lung function. The investigators will leave gas stoves in place but will instruct participants to preferentially use two relatively inexpensive portable electric appliances that the investigators will provide. Cooking will be done with an electric induction hot plate and baking with an electric toaster oven. Induction hot plates use magnetic coils beneath a ceramic glass surface to send electromagnetic pulses directly to cookware. The investigators will provide induction stove compatible cookware because it is necessary to use cookware that has some steel or iron in order for the energy transfer to work.
The two portable electric appliances and induction cookware are estimated to cost approximately $600 in total and may provide a more affordable option for low-income households. If a household already has a microwave oven, they will be encouraged to use that as well. As the future scalability of the intervention will depend on its usage, the investigators will also evaluate usage and identify facilitators and barriers to consistent use of the portable devices.
Interventions
- Other Portable cooking appliances
The investigators will leave gas stoves in place but will instruct participants to preferentially use two relatively inexpensive portable electric appliances that the investigators will provide. Cooking will be done with an electric induction hot plate and baking with an electric toaster oven.
Primary outcome measures
- Change in asthma control [Time frame: Baseline assessment 1-2 weeks before portable appliances given to participant. Final assessment 2-3 months after portable appliances given to participant.]
- Change in indoor nitrogen dioxide levels [Time frame: Baseline assessment 1-2 weeks before portable appliances given to participant. Final assessment 2-3 months after portable appliances given to participant.]
Secondary outcome measures (1)
- Change in forced expiratory volume in 1 second (FEV1) [Time frame: Baseline assessment 1-2 weeks before portable appliances given to participant. Final assessment 2-3 months after portable appliances given to participant.]
Eligibility criteria
Inclusion criteria
- Currently use gas stove for cooking or baking at least three times a week
- Poorly controlled asthma as defined by an Asthma Control Questionnaire score of 1.5 or larger
Exclusion criteria
- Impaired decision making capacity
- Pregnancy
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Crossover
- Masking
- Open label
- Primary purpose
- Treatment
Study locations
Center list to be confirmed — check the primary protocol.
Publications
- Bime C, Nguyen J, Wise RA. Measures of asthma control. Curr Opin Pulm Med. 2012 Jan;18(1):48-56. doi: 10.1097/MCP.0b013e32834db0f2. PMID 22081089
- Audignon-Durand S, Ramalho O, Mandin C, Roudil A, Le Bihan O, Delva F, Lacourt A. Indoor exposure to ultrafine particles related to domestic activities: A systematic review and meta-analysis. Sci Total Environ. 2023 Dec 15;904:166947. doi: 10.1016/j.scitotenv.2023.166947. Epub 2023 Sep 9. PMID 37690752
- Lebel ED, Finnegan CJ, Ouyang Z, Jackson RB. Methane and NOx Emissions from Natural Gas Stoves, Cooktops, and Ovens in Residential Homes. Environ Sci Technol. 2022 Feb 15;56(4):2529-2539. doi: 10.1021/acs.est.1c04707. Epub 2022 Jan 27. PMID 35081712
Identifiers
NCT: NCT07603206 · STUDY00001017