Not yet recruiting NCT07122518

Post-Approval Study of PALMAZ MULLINS XD™ in Treating Pulmonary Artery Stenosis

Observational Pulmonary Artery Stenosis

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: PALMAZ MULLINS XD™ Pulmonary Stent.
Who it may be relevant to
Registry conditions: Pulmonary Artery Stenosis. Basic parameters: up to 21 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Center list to be confirmed — check the primary protocol.
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

A Post-Approval Evaluation of the PALMAZ MULLINS XD™ Pulmonary Stent in the Treatment of Pulmonary Artery Stenosis (REALPASS)

Overview

The purpose of the clinical investigation is to characterize clinical outcomes and to assess the real-world use of the commercial PALMAZ MULLINS XD™ Pulmonary Stent.

Detailed description

The clinical study is a prospective, single-arm, multi-center, post-approval study of all consecutive subjects treated with the PALMAZ MULLINS XD™ Pulmonary Stent. The study will enroll a minimum of 35 subjects and a maximum of 75 subjects in up to 11 U.S sites or until the end of the 2-year enrollment period has been reached, whichever comes first.

The study will collect the performance and safety data of the PALMAZ MULLINS XD™ Pulmonary Stent through time of hospital discharge.

Interventions

  • Device PALMAZ MULLINS XD™ Pulmonary Stent
    The PALMAZ MULLINS XD™ Pulmonary Stent is indicated for the non-emergency treatment of pulmonary artery stenosis in pediatric patients who are at least 10kg in weight with two ventricle anatomy. The PALMAZ MULLINS XD™ Pulmonary Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is supplied unmounted and in five (5) nominal unexpanded lengths: 19 mm, 25 mm, 29 mm, 39 mm, and 59 mm.

Primary outcome measures

  • Technical Success (Successful use of the study device without additional, unplanned device or procedure-related surgery/re-intervention) [Time frame: Start time of index procedure through time of discharge/study completion, usually within ~48 hours from end time of index procedure]
  • Patency (Angiographically-determined increase in stented vessel minimum pulmonary artery diameter by ≥ 50% of the pre-stent diameter) [Time frame: Index procedure (start time to end time)]
  • Safety Outcome (Incidence of Treatment-Emergent Serious Adverse Events) [Time frame: Time of enrollment (device implant during index procedure) through time of discharge/study completion, usually within ~48 hours from end time of index procedure]

Eligibility criteria

\- Subjects \*should\* meet criteria as per the list of indications/contraindications in the Instructions for Use, though all subjects treated with PALMAZ MULLINS XD™ Pulmonary Stent will be considered eligible and enrolled.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Center list to be confirmed — check the primary protocol.