EB-OCT Biopsy Guidance of Lung Cancer
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Optical coherence tomography.
- Who it may be relevant to
- Registry conditions: Lung Cancer. Basic parameters: from 21 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Center list to be confirmed — check the primary protocol.
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Develop a High-resolution EB-OCT Platform to Visualize, Guide, Evaluate, and Increase the Accuracy of Lung Cancer Diagnosis in Human Subjects
Overview
Our objective is to develop, test, and validate a clinically robust polarization-sensitive optical coherence tomography (PS-OCT) biopsy guidance and diagnosis platform that is compatible with standard bronchoscopy techniques.
Detailed description
The goal of this study is to improve the unacceptably low diagnostic yield that is associated with low-risk bronchial biopsy. The investigators propose to do this by developing and optimizing a novel high-resolution optical coherence tomography (OCT) platform that will provide superior endomicroscopy images for biopsy guidance and in vivo diagnosis of lung cancer. OCT is a non-invasive imaging tool that rapidly generates high-resolution (\< 10 µm) cross-sectional images of biological tissues with penetration depths approaching 2-3 mm. Polarization Sensitive OCT (PS-OCT) provides additional contrast to structural OCT by highlighting birefringent tissues such as collagen. When coupled with appropriate catheter designs OCT can be used to conduct in vivo microscopy of tissue microstructure including the detection and diagnosis of cardiovascular, gastrointestinal, and lung pathology.
The objective of this study is to develop, test, and validate a clinically robust PS-OCT biopsy guidance and diagnosis platform that is compatible with standard bronchoscopy techniques. Specifically, the investigators envision two clinical scenarios:
Biopsy Guidance:
Following the identification and gross localization of a nodule by low-dose computed tomography (LDCT), a low-risk transbronchial biopsy will be acquired for diagnosis. Placement of the biopsy catheter will be performed using standard approaches including bronchoscopy, electromagnetic navigation, or robotic bronchoscopy. The investigators will then conduct PS-OCT at the site to (1) confirm that the biopsy catheter is correctly positioned within the nodule, and (2) ensure that diagnostic-quality tissue is obtained.
OCT Diagnosis:
For small isolated pulmonary nodules in vivo OCT imaging may open up the possibility of diagnosis and treatment within the same procedure. For larger pulmonary nodules OCT images of the tissue microstructure may also be used to provide complementary information to pathologists and treating physicians to help make a clinical diagnosis particularly when biopsy samples are inadequate. OCT can image a much larger volume of the tumor microenvironment than is possible with standard bronchial biopsy acquisition.
The advantages of this new platform over existing OCT technology include novel endobronchial catheters that include metalenses in their design. These catheters provide OCT images at significantly higher resolution over a greater depth of penetration than traditional OCT catheters. Our OCT platform will also incorporate cutting-edge polarization-sensitive OCT (PS-OCT) imaging capabilities which investigators have demonstrated are necessary to distinguish between tumor and non-diagnostic tissues including tumor-associated scar. PS-OCT is challenging to perform catheter-based imaging and extremely computationally expensive when it incorporates accurate catheter calibration and processing. Our endobronchial OCT imaging system will provide real-time intra-procedural processing which is critical for OCT biopsy guidance and diagnosis.
Interventions
- Device Optical coherence tomography
In the OCT-guided biopsy arm, n=100 study subjects will be enrolled. The investigators will conduct biopsies and imaging using our newly developed OCT catheters and real-time image processing and display algorithms.
Primary outcome measures
- Diagnostic yield of bronchial biopsy [Time frame: 2 years]
Secondary outcome measures (1)
- Determine the accuracy of OCT diagnosis of lung cancer in vivo by blinded reviewers. [Time frame: 2 years]
Eligibility criteria
Inclusion criteria
- Patients undergoing elective lung biopsy for known or suspected malignancy in the lung
- Patients must be over the age of 21
- Patient must be able to give informed consent
- Negative pregnancy test for all females of childbearing potential who are sexually active and not using contraception, are seeking to become pregnant, or are nursing
Exclusion criteria
- Patients who are pregnant
- The patient does not meet the requirements to undergo clinical bronchoscopy, as determined by the treating physician.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Double blind
- Primary purpose
- Other
Study locations
Center list to be confirmed — check the primary protocol.
Identifiers
NCT: NCT06556680 · 2024P001714 · 5R01HL133664-05