Menu
Not yet recruiting NCT07623837

Clinical Validation of AI-Based Quantitative Eye Movement Analysis From Smartphone 9-Gaze Videos (Glandy EOM)

Observational Ocular Motility Disorders Strabismus Extraocular Muscle Dysfunction Thyroid Eye Disease

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Glandy EOM (AI-based quantitative eye movement analysis software).
Who it may be relevant to
Registry conditions: Ocular Motility Disorders, Strabismus, Extraocular Muscle Dysfunction, Thyroid Eye Disease. Basic parameters: from 22 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
United States
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Prospective Multicenter Observational Study for Clinical Validation of AI-Based Quantitative Eye Movement Analysis Using Smartphone-Recorded 9-Gaze Videos

Overview

This prospective, multicenter, multinational observational study evaluates the clinical validity of an AI-based quantitative eye movement analysis system (Glandy EOM) that analyzes smartphone-recorded 9-gaze videos. Approximately 200 adults per site with suspected or confirmed ocular motility abnormalities will undergo a single study visit consisting of a standard clinical 9-gaze examination, an assistant-aided smartphone video recording, and a patient self-recorded video acquisition using a mobile application. Because the study population is defined by clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population and are not considered healthy volunteers. AI-derived quantitative eye movement metrics (corneal center displacement in millimeters and angular deviation) will be compared with rater-derived measurements obtained from the same videos using a calibrated reference approach, and with clinician-assessed 9-gaze grading. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making.

Detailed description

Ocular motility is commonly evaluated using the 9-gaze examination, which relies on clinician observation and semi-quantitative grading. This approach is inherently subjective and can show inter-observer variability and limited sensitivity to subtle changes over time. Objective, quantitative assessment of eye movement remains an unmet clinical need, particularly for monitoring disease progression and treatment response.

Recent advances in artificial intelligence have enabled automated analysis of facial and ocular features from smartphone-recorded videos, offering the potential for reproducible quantitative measurement of eye movement. Glandy EOM is an investigational software-only medical device (SaMD) developed by THYROSCOPE INC. that processes smartphone-recorded 9-gaze videos to generate quantitative eye movement metrics. Glandy EOM has not yet received regulatory approval and is used for research purposes only in this study.

The study is a prospective, multicenter, multinational observational investigation designed to evaluate the clinical validity of Glandy EOM. The study population consists of adults with suspected or confirmed ocular motility abnormalities; healthy volunteers without any clinical indication for 9-gaze examination are not enrolled. Because eligibility is based on clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may ultimately be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population. Participants will undergo a single study visit consisting of (1) a standard clinical 9-gaze examination with clinician grading (-4 to +4), (2) a smartphone video recording performed with the assistance of a trained operator using a standardized setup, and (3) a patient self-recorded smartphone video acquired through the study mobile application.

For quantitative reference measurements, independent rater-derived measurements will be obtained from the recorded videos using a calibrated reference approach. A calibration marker of known size will be placed on the glabella during video acquisition to enable real-world scale estimation for the reference measurements. The calibration marker is used only for rater-based reference measurement and is not used by the AI algorithm.

The primary objective is to evaluate agreement between AI-derived quantitative eye movement metrics and rater-derived measurements of corneal center displacement, expressed as distance (mm) and angular deviation. Secondary objectives are to evaluate correlation between AI-derived metrics and clinician-assessed 9-gaze grading, and to evaluate whether AI-derived metrics obtained from patient self-recorded videos are comparable to those obtained from assistant-aided recordings. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making during the study.

Interventions

  • Device Glandy EOM (AI-based quantitative eye movement analysis software)
    Glandy EOM is an investigational software-only medical device developed by THYROSCOPE INC. It has not yet received regulatory approval and is used for research purposes only in this study. Glandy EOM processes smartphone-recorded 9-gaze facial videos to generate AI-derived quantitative eye movement metrics: * Corneal center displacement (mm) * Angular deviation (degrees) Video acquisition in this study includes (a) an assistant-aided recording using a standardized smartphone setup in the clinic

Primary outcome measures

  • Agreement between AI-derived and rater-derived corneal center displacement (distance, mm) [Time frame: At study visit (single visit)]
  • Agreement between AI-derived and rater-derived angular deviation (degrees) [Time frame: At study visit (single visit)]
  • Linear association and absolute error vs. rater-derived reference [Time frame: At study visit (single visit)]
Secondary outcome measures (4)
  • Correlation between AI-derived metrics (assistant-aided recording) and clinician-assessed 9-gaze grading [Time frame: At study visit (single visit)]
  • Correlation between AI-derived metrics (patient self-recorded) and clinician-assessed 9-gaze grading [Time frame: At study visit (single visit)]
  • Agreement between AI-derived metrics from patient self-recorded vs. assistant-aided recordings [Time frame: At study visit (single visit)]
  • Linear association and absolute error: patient self-recorded vs. assistant-aided [Time frame: At study visit (single visit)]

Eligibility criteria

Inclusion criteria

  • Adults who have reached the legal age of consent for research participation in the applicable jurisdiction.
  • Subjects with suspected or known ocular motility abnormalities.
  • Subjects who are able to understand and follow gaze instructions required for the 9-gaze examination, as judged by the investigator.
  • Subjects who are able to undergo facial video recording using a smartphone.
  • Subjects who provide written informed consent.

Exclusion criteria

  • Conditions that prevent reliable detection of ocular landmarks in video recordings (e.g., severe ptosis, corneal opacity, or significant occlusion of the eyes).
  • Ocular or facial conditions that, in the opinion of the investigator, may significantly interfere with image-based analysis.
  • Subjects who are unable to comply with study procedures.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

United States · 1 center
  • 3003 North First Street #221 — San Jose

Identifiers

NCT: NCT07623837 · THYROSCOPE-EOM-2026-01

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗