NeoSHARK: Anatomical Versus Round Facemasks for Breathing Support in Preterm and Term Newborn Infants
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Intervention: Anatomical facemask, Control: Round facemask.
- Who it may be relevant to
- Registry conditions: Neonatal Intensive Care. Basic parameters: No limits · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Ireland
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
NeoSHARK: Neonatal Study of Two-Handed Anatomical Versus Round facemasK Ventilation in Preterm and Term Infants; a Randomised Controlled Trial
Overview
When babies can't breathe effectively, we can use a facemask to give them breaths and oxygen. There are various types of facemasks that can be used, including round and anatomical (triangular) masks, depending on the preference of the hospital, but it is unclear if one is better for the baby. Both types of facemasks are recommended in international guidelines, without any advice whether one is better than the other. Previous studies published by our research group demonstrated that a variety of different masks are used around the hospitals in Ireland. If a lot of air is leaking around the mask, it means that the baby is not getting the full breathing support that we are trying to give. We currently do not have enough evidence to say which type of mask is better to reduce the risk of this potential leaking of air. Recent studies have suggested that holding a mask with two hands (instead of one) is better in round facemasks. The combination of an anatomical mask and a two-handed hold has not yet been studied in babies. In this study, we will compare two different facemasks (round and anatomical) when holding the mask on a baby's face with two hands to help them breathe. We will randomly allocate each baby to either a round mask or an anatomical (triangular) mask and we will measure how much air leaks out around the mask during each breath. We will do this in babies who are in the neonatal unit.
Detailed description
Delivering effective facemask ventilation is an essential component of neonatal resuscitation. However, facemask leak of up to 60% in preterm neonates and airway obstruction are common and can be associated with ineffective ventilation of the baby and clinical instability (O'Currain 2019). Multiple characteristics may influence the effectiveness of facemask ventilation, such as operator technique, infant gestation, airway anatomy and tone, as well as facemask size and shape.
The Neonatal Resuscitation Programme (NRP) allows for either type of facemask as per local practice, without recommending a particular shape of that facemask. A recent national airway survey by our group demonstrated that 8/19 centres in Ireland use both anatomical and round facemasks in clinical practice, with 11 different sizes and shapes of facemasks in clinical use in neonatal units in Ireland. While studies to date have not found a difference between anatomical and round masks in neonatal manikins, these studies only included facemask ventilation delivered with a one-handed hold, rather than a two-handed hold. Emerging evidence, including benchtop and clinical data, suggests that a two-handed hold is superior to a one-handed hold in round facemasks. The combination of an anatomical mask and a two-handed hold has not yet been studied in a clinical setting.
This study will compare the measured leak in mask ventilation with a two-handed hold, delivered by a healthcare professional in the neonatal team, using an anatomical versus a round facemask with standardised mask size. The facemasks will be assessed by a randomised controlled trial, with the anatomical mask as the intervention and the round mask as the control. The population that will be studied is neonates in the neonatal intensive care unit (NICU), at any gestation, who the clinical team have decided to intubate. A member of the research team, who will provide an out-of-hours on call service, will attend the event. The relevant outcomes will be measured by the Monivent Neo100, which will be set up by the research team. Standardised mask size, as per local protocol, will be used, with the sensor module placed between the mask and the T-piece with an adaptor. The outcomes will assess the effectiveness of both the intervention and control, including ventilation parameters recorded by the Monivent Neo100 and the clinical stability of the patient. The primary outcome of this study is the percentage mask leak. A research team member will record data for primary and secondary outcomes. The event will be filmed for post-hoc video analysis. The outcome assessor will be blinded to the group allocation.This research project will take place over 10 months, with an interim analysis to ensure recruitment is projected to achieve sample size.
Interventions
- Device Intervention: Anatomical facemask
Anatomical facemask, with a two-handed hold, to deliver positive pressure ventilation via a mask. - Device Control: Round facemask
Round facemask, with a two-handed hold, to deliver positive pressure ventilation via a mask.
Primary outcome measures
- Mask leak [Time frame: Over a maximum of 20 minutes]
Secondary outcome measures (10)
- Lowest oxygen saturation [Time frame: Over a maximum of 20 minutes]
- Highest supplemental FiO2 used during facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Positive inspiratory pressure during facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Percentage of obstructed breaths during facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Tidal volume during facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Number of times facemask position is adjusted during facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Duration of facemask ventilation [Time frame: Over a maximum of 20 minutes]
- Crossover to other handhold [Time frame: Over a maximum of 20 minutes]
- User opinion of mask hold [Time frame: Over a maximum of 20 minutes]
- Lowest heart rate [Time frame: Over a maximum of 20 minutes]
Eligibility criteria
Inclusion criteria
- All term and preterm neonates in the neonatal unit who the clinical team have decided to intubate, with or without pre-medication, and who require mask ventilation prior to intubation attempt.
Exclusion criteria
- Neonates with a congenital malformation that would impact mask seal will not be included.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Single blind
- Primary purpose
- Supportive care
Study locations
Ireland · 1 center
- The National Maternity Hospital Dublin — Dublin
Publications
- Lorenz L, Ruegger CM, O'Currain E, Dawson JA, Thio M, Owen LS, Donath SM, Davis PG, Kamlin COF. Suction Mask vs Conventional Mask Ventilation in Term and Near-Term Infants in the Delivery Room: A Randomized Controlled Trial. J Pediatr. 2018 Jul;198:181-186.e2. doi: 10.1016/j.jpeds.2018.03.013. Epub 2018 Apr 25. PMID 29705115
- Shah D, Tracy MB, Hinder MK, Badawi N. One-person versus two-person mask ventilation in preterm infants at birth: a pilot randomised controlled trial. BMJ Paediatr Open. 2023 Feb;7(1):e001768. doi: 10.1136/bmjpo-2022-001768. PMID 36746525
- O'Currain E, O'Shea JE, McGrory L, Owen LS, Kamlin O, Dawson JA, Davis PG, Thio M. Smaller facemasks for positive pressure ventilation in preterm infants: A randomised trial. Resuscitation. 2019 Jan;134:91-98. doi: 10.1016/j.resuscitation.2018.12.005. Epub 2018 Dec 17. PMID 30572069
Identifiers
NCT: NCT07524517 · EC05.2026