Menu
Not yet recruiting NCT07379697

Measuring Local Potentials in PFA. MULTI PFA (EU)

Observational Atrial Fibrillation (AF)

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
This is an observational study: the protocol does not assign a study treatment.
Who it may be relevant to
Registry conditions: Atrial Fibrillation (AF). Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Center list to be confirmed — check the primary protocol.
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

The Feasibility of Measuring Unipolar Atrial Local Potentials From a Range of Pulsed Field Ablation Catheters. The MULTI PFA (EU) Study

Overview

The study is a prospective, multi-center, exploratory, observational study with the ECGenius® System and the PFAnalyzer software module in PFA cases using the Affera Sphere 9, FaraWave, PulseSelect, Volt or VariPulse PFA systems. The cohort will be adult patients with paroxysmal or persistent atrial fibrillation (AF) who undergo PVI using PFA.

Detailed description

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with a five-fold increase in stroke. Pulmonary vein isolation (PVI) has become a first-line treatment for paroxysmal AF. PVI is achieved by ablating cardiac tissue around the pulmonary veins. Until recently, this has been achieved using thermal energy. However, more recently a new energy source known as pulsed field ablation (PFA) has been introduced. As PFA is tissue selective, it preserves the function of nearby structures such as the esophagus and phrenic nerve making it safer to use. As PFA is delivered in short bursts of high energy, it is also more efficient and leads to shorter procedures. However, the catheters designed to deliver PFA differ to those used previously and do not provide the same information about efficacy, making it more difficult for the operator to ascertain if the lesions have successfully isolated the pulmonary vein. This exploratory observational study will assess the utility of a software module designed to measure the local potential derived from the unipolar electrogram recorded at the electrode that has delivered the PFA. During the procedure, the study will collect data only and all analysis of the output of the PFAnalyzer software module will be made off-line once the procedure is complete. The operator will follow the hospital's standard of care during the procedure, and the software module will not be used to guide therapy, nor will there be any additional time added to the procedure.

The study is a prospective, multi-center, exploratory, observational study with the ECGenius® System and the PFAnalyzer software module in PFA cases using the Affera Sphere 9, FaraWave, PulseSelect or VariPulse PFA systems. The cohort will be adult patients with paroxysmal or persistent atrial fibrillation (AF) who undergo PVI using PFA.

Primary outcome measures

  • Identify a clinically meaningful threshold for residual potentials after PFA delivery [Time frame: At the time of the procedure]
  • Identify a clinically meaningful threshold for residual potentials after PFA delivery [Time frame: At the time of the procedure]

Eligibility criteria

Inclusion criteria

  • Subjects undergoing first time pulmonary vein isolation indicated by investigator for the treatment of atrial fibrillation.
  • Male or non-pregnant female aged ≥18 years.
  • Able and willing to provide written informed consent prior to any clinical investigation related procedure.
  • Subjects in sinus rhythm at the time of the PFA application.

Exclusion criteria

  • Pregnant or nursing subjects.
  • Current participation in another investigational drug or device study that interferes with this study.
  • Subjects who, in the opinion of the investigator, are not candidates for this study.
  • Patients who have had a prior ablation procedure.
  • Presence of other anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results.
  • Life expectancy is less than 12 months, in the opinion of the investigator.
  • Subjects who, in the opinion of the investigator, are considered part of any vulnerable population.
  • Subjects unlikely to be in sinus rhythm at the time of the procedure or unlikely to remain in sinus rhythm after cardioversion

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Center list to be confirmed — check the primary protocol.

Identifiers

NCT: NCT07379697 · CVPFA-004

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗