Menu
Recruiting NCT07370467

Transcatheter Mitral and Tricuspid Interventions: a Cardiac Magnetic Resonance Study

Observational Mitral Insufficiency Transcatheter Aortic Valve Replacement

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
This is an observational study: the protocol does not assign a study treatment.
Who it may be relevant to
Registry conditions: Mitral Insufficiency, Transcatheter Aortic Valve Replacement. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Italy
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

TEMATIC-MR: Transcatheter Mitral and Tricuspid Interventions: a Cardiac Magnetic Resonance Study

Overview

Mitral and tricuspid valve disease represents an increasing challenge in the management of patients with heart failure and other cardiovascular diseases. In recent years, the introduction of transcatheter techniques for valve repair and replacement (TVI) has revolutionised the treatment of these diseases, particularly for patients at high surgical risk or who are not candidates for traditional surgery. However, although these procedures are increasingly popular, their long-term effectiveness in terms of cardiac remodelling is still not well understood. Cardiac magnetic resonance (CMR) techniques, with their advanced capabilities to provide anatomical and functional details of the heart, offer a unique opportunity to assess ventricular remodelling and valve function before and after transcatheter interventions. The ESC guidelines on valvulopathies published in 2021 recommend the use of cardiac magnetic resonance imaging not only to quantify the extent of mitral and tricuspid regurgitation when echocardiography is inconclusive, but also as the gold standard for the assessment of left and right ventricular size and function (limited, however, to the availability of this method in the various centres). Currently, there are few systematic data evaluating the effect of these procedures on CMR-assessed cardiac anatomy and function. This study aims to fill this gap by creating a multicentre registry in which clinical and advanced imaging data, including 3D echocardiography and CMR, are collected to assess the impact of these therapies. Analysis of data derived from advanced imaging will not only provide a better understanding of the mechanism of operation of transcatheter techniques, but will also provide important information for improving long-term patient outcomes by identifying potential predictors of treatment success or failure.

Detailed description

Mitral and tricuspid valve disease represents an increasing challenge in the management of patients with heart failure and other cardiovascular diseases. In recent years, the introduction of transcatheter techniques for valve repair and replacement (TVI) has revolutionised the treatment of these diseases, particularly for patients at high surgical risk or who are not candidates for traditional surgery. However, although these procedures are increasingly popular, their long-term effectiveness in terms of cardiac remodelling is still not well understood.

Cardiac magnetic resonance (CMR) techniques, with their advanced capabilities to provide anatomical and functional details of the heart, offer a unique opportunity to assess ventricular remodelling and valve function before and after transcatheter interventions. The ESC guidelines on valvulopathies published in 2021 recommend the use of cardiac magnetic resonance imaging not only to quantify the extent of mitral and tricuspid regurgitation when echocardiography is inconclusive, but also as the gold standard for the assessment of left and right ventricular size and function (limited, however, to the availability of this method in the various centres). Currently, there are few systematic data evaluating the effect of these procedures on CMR-assessed cardiac anatomy and function. This study aims to fill this gap by creating a multicentre registry in which clinical and advanced imaging data, including 3D echocardiography and CMR, are collected to assess the impact of these therapies.

Analysis of data derived from advanced imaging will not only provide a better understanding of the mechanism of operation of transcatheter techniques, but will also provide important information for improving long-term patient outcomes by identifying potential predictors of treatment success or failure.

Primary outcome measures

  • Cardiac Remodelling [Time frame: 12 months]
Secondary outcome measures (1)
  • Analize imaging data [Time frame: 12 months]

Eligibility criteria

Inclusion criteria

  • Age ≥ 18 anni
  • Signing informed consent
  • Patients who are candidates for transcatheter mitral or tricuspid surgery (TEER, TTVR).

Exclusion criteria

  • Age < 18 years
  • Contraindications to CMR or administration of contrast medium (gadolinium)

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Italy · 1 center
  • Centro Cardiologico Monzino — Milan

Identifiers

NCT: NCT07370467 · L2-273

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗