Recruiting NCT07298356

Automated Applanation Tonometry - Updated

No phase Interventional Glaucoma Glaucoma, Suspect

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Standard GAT, Fixed force GAT, Upright applanating prototype, Pneumotonometer.
Who it may be relevant to
Registry conditions: Glaucoma, Glaucoma, Suspect. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
United States
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →

Overview

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. Another clinical standard for checking eye pressure is known as the pneumotonometer. This method is more objective but not portable. The purpose of this study is to develop new methods of measuring eye pressure that are more objective, reproducible and portable. In this study, the investigators will be comparing the eye pressure measurements using 2 investigational methods to GAT and pneuumotonometer.

Detailed description

This is a prospective study. Patients presenting for their scheduled eye appointments will be recruited by verbal communication. Following informed consent, intraocular pressure (IOP) measurements will be made by the following methods:

Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.

Pneumotonometer: This is what is done in routine eye care. The participant will receive a topical anesthetic (numbing agent). A probe will touch the front of the eye while the machine measures the eye pressure.

Fixed force GAT: From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a complementary metal oxide semiconductor (C-MOS) camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPod touch camera has been previously published by this PI.

Upright applanating prototype: With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter.

The order of the above 4 measurements will be randomized.

Interventions

  • Device Standard GAT
    Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice
  • Device Fixed force GAT
    An investigational device similar to standard GAT
  • Device Upright applanating prototype
    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device
  • Device Pneumotonometer
    This is a standard for checking eye pressure. A topical anesthetic (numbing agent). A probe will touch the front of the eye while the machine measures the eye pressure

Primary outcome measures

  • Intraocular pressure (IOP) as measured by standard GAT [Time frame: Baseline]
  • Intraocular pressure (IOP) as measured by fixed force GAT [Time frame: Baseline]
  • Intraocular pressure as measured by upright applanating [Time frame: Baseline]
  • Intraocular pressure as measured by supine Pneumotonometer [Time frame: Baseline]

Eligibility criteria

Criteria:

Inclusion criteria

  • Presenting for a routine eye exam
  • ≥ 18 years of age
  • Able and willing to give consent

Exclusion criteria

  • History of corneal scarring
  • Active infection of the eye
  • Ocular surface trauma or infection

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Randomized
Model
Parallel assignment
Masking
Open label
Primary purpose
Diagnostic

Study locations

United States · 1 center
  • Duke Eye Center — Durham

Identifiers

NCT: NCT07298356 · Pro00106111_1

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗