Menu
Not yet recruiting NCT07089017

Anesthetic Management Guided by the Medstrom Instrument

No phase Interventional Pain Management

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: medstrom仪器.
Who it may be relevant to
Registry conditions: Pain Management. Basic parameters: 18 years — 65 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Center list to be confirmed — check the primary protocol.
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Evaluation of the Feasibility of the Medstrom Medical Device in Laparoscopic Radical Colectomy for Colorectal Cancer

Overview

This clinical trial seeks to evaluate the feasibility of the Medstrom device for integrated real-time monitoring of pain, sedation, and neuromuscular blockade during laparoscopic radical colectomy. By addressing limitations of conventional multi-device monitoring systems-including data conflicts, interpretation delays, and elevated costs-the study examines whether Medstrom can comprehensively assess intraoperative patient status and effectively guide anesthesia management using validated reference metrics. Key questions being investigated include: 1. Whether Medstrom can concurrently generate reliable pain, sedation, and neuromuscular indices through a single platform, and if these outputs demonstrate significant correlation with gold-standard measures (HRV for pain, BIS for sedation, TOF for neuromuscular blockade); 2. Whether integrated monitoring reduces intraoperative decision latency (e.g., accelerated pain detection) and mitigates inter-device interference (e.g., BIS distortion by neuromuscular agents); 3. Whether Medstrom introduces device-related adverse events (e.g., cutaneous irritation, signal misinterpretation) while potentially reducing anesthesia complications (e.g., respiratory depression, intraoperative awareness). Researchers will randomize patients undergoing elective laparoscopic radical colectomy into two groups: 1. Group T(Medstrom -guided):an intervention group receiving continuous multimodal monitoring via Medstrom, 2. Group C (Conventional):a control group undergoing conventional monitoring (BIS + TOF + hemodynamic parameters). Synchronized data will be captured at eight predefined intraoperative timepoints for correlation analysis between Medstrom-derived indices and conventional metrics.

Detailed description

This prospective randomized controlled trial (RCT) aims to evaluate the feasibility and safety of the integrated Medstrom monitoring system for real-time, comprehensive assessment of pain, sedation level, and neuromuscular blockade (NMB) during laparoscopic radical colectomy. It addresses significant limitations of conventional fragmented monitoring systems, such as data conflicts between independent devices (e.g., BIS for sedation, TOF for NMB, HRV for pain), delayed clinical interpretation, and suboptimal resource utilization.

The Medstrom technology utilizes palmar/plantar PAM sensors to objectively quantify pain via skin conductance peaks (SCP). SCPs are generated by emotional sweating triggered via spinal nociceptive reflexes, offering key advantages: objective pain quantification (SCP amplitude correlates with stimulus intensity), rapid response (within 1-2 seconds to noxious stimuli), resilience against hemodynamic instability, temperature variations, or medications, and the unique capability to simultaneously output validated sedation and neuromuscular indices. This single-device integration aims to replace the need for separate BIS, TOF, and HRV monitors.

The study design involves 45 patients (adjusted for 10% dropout from n=40) aged 18-65 years with ASA physical status I-III and confirmed colon cancer, undergoing elective laparoscopic radical colectomy. Key exclusions include BMI ≥30, significant organ dysfunction, neurological/neuromuscular disorders, and pregnancy. Participants are randomized into two groups:

1. Medstrom-Guided Group (Intervention): Continuous monitoring using palmar/plantar sensors with real-time display of integrated pain, sedation, and NMB indices guiding anesthesia management. 2. Conventional Monitoring Group (Control): Standard care using separate BIS (target 40-60) + TOF + standard hemodynamic monitoring.

A standardized anesthesia protocol is employed for both groups: Induction with Propofol (1.5-2.5 mg/kg) + Sufentanil (0.2-0.4 μg/kg) + Rocuronium (0.6-1.0 mg/kg), and Maintenance with Propofol (4-12 mg/kg/h) + Remifentanil (0.1-0.2 μg/kg/min) + bolus Rocuronium/Sufentanil as needed. Data collection occurs at 8 critical intraoperative timepoints, including intubation, skin incision, pneumoperitoneum, surgical end, and pre/post supplemental sufentanil administration.

The primary endpoints focus on establishing the feasibility and correlation of the Medstrom indices against current gold standards:

• Correlation of Medstrom-Pain vs. HRV (Pearson/Spearman).

Feasibility is defined by statistically significant correlations (p\<0.05, adjusted for multiple comparisons using Bonferroni/Dunn-Šidák).

Secondary outcomes include hemodynamic stability (HR/MAP fluctuations), total anesthetic consumption, device-related adverse events (e.g., skin irritation, signal errors), and analysis of interactions between the integrated indices (using SEM/pathway analysis).

The statistical approach is based on a sample size of 40 (calculated for multivariate repeated measures: α=0.05, β=0.1/power=90%, effect size f²=0.15, variable correlation ρ=0.4), increased to N=45 to account for a 10% dropout rate. Analyses include correlation (95% CIs), consistency (Bland-Altman/ICC for agreement), multivariable comparisons (Hotelling's T² for correlated outcomes), and time effects (Linear mixed models with random intercepts).

This study holds innovative significance as the first RCT to validate a single-device, triple-parameter integrated monitoring system (pain, sedation, NMB) specifically in major abdominal surgery. It addresses critical clinical gaps: providing objective pain quantification (replacing subjective hemodynamic interpretation), minimizing device interference issues (e.g., BIS distortion by neuromuscular agents), and enhancing resource efficiency. The potential clinical impact includes reducing the risk of intraoperative awareness/pain recall and establishing a framework for more cost-effective and streamlined anesthesia management.

Interventions

  • Device medstrom仪器
    In addition to conventional monitoring methods, such as electrocardiography (ECG), bispectral index (BIS), and train-of-four (TOF) monitoring, Medstrom instruments were utilized to assess and monitor the patient's pain, sedation, and muscle relaxation status.

Primary outcome measures

  • Correlation between HRV and the Medstrom Instrument Pain Index [Time frame: From the beginning to the end of the operation]
Secondary outcome measures (4)
  • Heart rate [Time frame: From the beginning to the end of the operation]
  • The total amount of anesthetic drugs [Time frame: From the beginning to the end of the operation]
  • Interaction of related indicators [Time frame: From the beginning to the end of the operation]
  • Mean arterial pressure [Time frame: From the beginning to the end of the operation]

Eligibility criteria

Inclusion criteria

  • 1\. Timeframe \& Location: Patients treated at the First Medical Center of the Chinese PLA General Hospital between June 2025 and December 2026.

2\. Age: 18 to 65 years old. 3. Diagnosis: Pathologically confirmed colon cancer requiring laparoscopic radical resection.

4\. Physical Status: American Society of Anesthesiologists (ASA) Physical Status Class I-III.

5\. Informed Consent: Patients who voluntarily participate in the study and provide written informed consent.

Exclusion criteria

\- 1. Body Mass Index (BMI): BMI ≥ 30 kg/m². 2. Organ Dysfunction: Severe concomitant cardiac, pulmonary, hepatic, or renal dysfunction.

3\. Neurological Conditions:

  • History of autonomic nervous system disorders.
  • Current use of medications affecting autonomic nervous system function.
  • History of neuromuscular dysfunction. 4. Pregnancy/Lactation: Pregnant or lactating women. 5. Recent Surgery: History of secondary surgery within the preceding month. 6. Psychiatric/Cognitive Conditions:
  • History of psychiatric disorders or cognitive impairment.
  • History of psychotropic or narcotic drug abuse.
  • Significant communication barriers.

Withdrawal Criteria:

1.Requirement for conversion to open surgery or other significant deviation from the planned laparoscopic approach due to intraoperative findings.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Randomized
Model
Parallel assignment
Masking
Single blind
Primary purpose
Other

Study locations

Center list to be confirmed — check the primary protocol.

Identifiers

NCT: NCT07089017 · PLAGH-L03

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗