Patient Satisfaction in Occlusal Splints Fabricated Using Fully Digital Versus Conventional Workflow
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Occlusal splints manufactured with fully digital workflow., Occlusal splints manufactured with Conventional workflow.
- Who it may be relevant to
- Registry conditions: Temporomandibular Joint Disorders. Basic parameters: 18 years — 40 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Center list to be confirmed — check the primary protocol.
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Patient Satisfaction and Occlusal Adjustments in Occlusal Splints Fabricated Using Fully Digital Versus Conventional Workflow in TMD Patients. (Randomized Controlled Clinical Trial)
Overview
According to published literatures, the prevalence of TMD is approximately 10% in patients over 18 years of age with a considerable proportion being women of reproductive age. The treatment of TMD presents the following goals: decreasing joint and masticatory muscle pain, increasing the range of motion in the mandible, preventing degenerative changes in the articulating tissues. Management of TMD can be either conservative or surgical treatments, the conservative treatments include analgesia, medications, physical therapy, occlusal adjustment, splint therapy, localized steam application, and external muscle massage. The occlusal splint therapy is considered a common treatment option for TMD management. Flat stabilization splint is the preferred splint for such cases. It is designed to promote occlusal stability and decrease muscles tension by altering occlusion and allowing complete seating of the condyle in centric relation. The evolution of digital technology created new era of dentistry that successfully digitalized the traditional workflow of occlusal splints including designing and manufacturing. Furthermore, virtual facebow and dynamic jaw relation record using jaw tracking device are another digital reward. The digital workflow can offer more predictable approach for occlusal splint construction, It could eliminate the traditional technical errors and enhance the occlusal accuracy
Detailed description
The traditional workflow of occlusal splints includes, primary impression for both arches, pouring casts, patient deprogramming and centric jaw relation record followed by mounting. Then the occlusal splint is made out of a resin that includes wax pattern fabrication on surveyed and mounted casts to be invested finally to form a clear, heated-cured acrylic resin splint. After that, it is trimmed, polished, and seated back on the duplicate of the invested casts. It is a complicated process and time- consuming constructed followed by occlusal adjustments on the articulator. That traditional approach is time consuming and prone to many technical errors. Such errors are reflected in occlusal discrepancies that are considered critical for the effectiveness of occlusal splint therapy.
Recent advancements in the field of intra-oral scanning (IOS), jaw tracking device for digitally recording the maxillomandibular relationship, maximum intercuspation, centric occlusion and the patient's mandibular motion. This technique incorporates the mandibular motion into the 3-dimensional (3D) virtual patient representation to integrate the 3D dynamic virtual patient visualization and computer-aided design/computer-aided manufacturing (CAD/CAM) may have the potential to compensate for some of the shortcomings of conventional splint therapy and deliver improved clinical results, while simplifying the workflow. Several studies have shown the improved quality and material properties of CAD/CAM splints in comparison to conventional ones, but little of them reported fully digital workflow starting from scanning of maxillary and mandibular teeth, using jaw tracking device to obtain personalized condylar motion parameters and individualized maxillary position to better simulate the actual movement of the patient in the laboratory (Revilla, Marta etal,2022) and Computer-aided design/computer-aided manufacturing (CAD/CAM) in final production of occlusal splints all of these fully digital steps may be possibly reducing the adjustment time for occlusal devices and achieving predictable efficacy.
This study aims to compare the difference, if present in patient satisfaction and the amount of occlusal adjustments in occlusal splints fabricated using fully digital versus conventional workflow.
Interventions
- Device Occlusal splints manufactured with fully digital workflow.
The intervention involves the fabrication of 3D printed occlusal splint with fully digitalization technique by the aid of Jaw Tracing Device. The acquisition and scanning of the patients are done by using an intra oral scanner and designing them using a designing software. This device will be printed with a 3D printer utilizing printable resin material - Device Occlusal splints manufactured with Conventional workflow
For the comparator group, maxillary and mandibular impressions will be made with Cavex CA37 alginate impression material (Cavex Holland B.V, Holland), models will be poured with gypsum (Kimberlit, Type IV Dental Stone, Protechno Spain), facebow (Bio-art) record and interocclusal registrations will be recorded at centric by using bite registration material after patient deprogramming with Lucia jig. The models will be mounted in a semi-adjustable articulator (Bio-art, A7Plus, Brazil), wax pattern
Primary outcome measures
- Patient satisfaction [Time frame: '' Up to 12 weeks'']
Secondary outcome measures (1)
- Amount of occlusal adjustments [Time frame: Base line or day 1]
Eligibility criteria
Inclusion criteria
- 18-40 years old
- Complete dentition.
- Normal jaw opening.
- Intact teeth.
- No ongoing dental therapy, such as orthodontic or prosthodontic treatment.
- TMD patients with more than one of following symptoms or signs: myofascial pain and /or pain in the TMJ, myofascial pain and/or pain in the TMJ on palpation, muscles tenderness, headache or earache.
- Patients who had unsuccessfully undergone splint therapy or other TMD treatments in the past were not excluded.
Exclusion criteria
- Patients with systemic diseases which could affect TMJ, e.g., rheumatoid arthritis, osteoarthrosis, osteoporosis, and patients taking analgesic, muscle relaxant, or anti inflammatory drugs were excluded because such drugs could influence the results.
- Temporomandibular joint lesions found on clinical palpation or medical imaging examination.
- Jaw opening less than 3 fingers.
- Patients with occlusal dysfunctions.
- Patients with severe or moderate periodontitis.
- Unable to undergo examination or treatment due to the presence of a psychological or mental disorder.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Single blind
- Primary purpose
- Treatment
Study locations
Center list to be confirmed — check the primary protocol.
Identifiers
NCT: NCT06985173 · PROSR 3-3-32025