Menu
Recruiting NCT06951594

Robotic-Assisted Versus Manual Electrode Array Insertion

No phase Interventional Cochlear Implantation Robotics

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Robotic.
Who it may be relevant to
Registry conditions: Cochlear Implantation, Robotics. Basic parameters: 18 years — 80 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
United States
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Iowa Cochlear Implant Clinical Research Center Study on Robotic-Assisted Versus Manual Electrode Array Insertion

Overview

Robotics-assisted electrode insertion overcomes many surgeon-related kinetic limitations such as insertion speed, tremor, drift, and lack of accurate force control. In human cadaveric cochleae, robotics-assisted electrode insertion causes less intracochlear trauma compared to manual insertion. Whether this technical advance results in functional benefits in CI patients remains unknown. To address this critical knowledge gap, the investigators will compare cochlear trauma assessed using CT scans, cochlear and AN function assessed using ECochG and/or the eCAP, and clinical outcomes quantified by postoperative residual acoustic hearing and speech perception scores between participants randomized to either manual or robotics-assisted electrode array insertion.

Detailed description

Electrode insertion force is a critical determinant of the degree/amount of intracochlear trauma caused by CI surgery. It is affected by the speed of electrode array insertion, with higher insertion speeds leading to greater insertion forces. In addition, rapid electrode array insertions with higher forces are associated with translocation of electrode arrays from the scala tympani into the scala media or vestibuli which leads to lower performance and higher rates of loss of residual hearing. Furthermore, variability in insertion force during electrode insertion can cause dramatic increases in intracochlear fluid pressure which appears to be traumatic. The recent FDA-approved iotaSOFT™ insertion system is designed to address these issues by controlling the speed of implant insertion (0.1-1.0 mm/sec) with reduced insertion force and variability. Use of the iotaSOFT™ insertion system significantly reduces the maximum insertion force, variation in insertion force and intracochlear pressure changes over time, which leads to decreased intracochlear trauma compared with manual insertion in cadavers. In addition, this robotics-assisted insertion system can be used with ECochG monitoring systems, which enables response dynamics that can dramatically reduce electrode array stopping distances (1-2 µm of further electrode array advancement) compared to the kinetics of human manual insertion (\~1 mm) once a change in intraoperative ECochG response is detected. Theoretically, robotics-assisted electrode array insertion should result in better preserved structural and functional integrity of the peripheral auditory system due to reduced intracochlear trauma. However, this theoretical possibility has not been tested in human CI users.

To address this knowledge gap, the investigators propose to determine the functional benefits of using robotics-assisted electrode insertion in reducing intracochlear trauma. This will be achieved by comparing trauma to the cochlea from electrode insertion based on postoperative CT scans, electrode impedance, the functional status of the cochlea and the AN, as well as preservation of acoustic hearing in participants randomized to have the electrode array inserted manually or with the iotaSOFT™ insertion system. The investigators hypothesize that robotics-assisted electrode insertion will better preserve peripheral structural and functional integrity by reducing intraoperative trauma. The investigators expect that participants with robotics-assisted electrode insertions will show smaller trauma scores based on CT scans, lower electrode impedance, better functional statuses of the AN, higher ENI indices, less hearing loss, and improved speech perception scores than participants with manual electrode insertions.

Interventions

  • Device Robotic
    The iotaSOFT™ Insertion System is an FDA approved cochlear implant (CI) electrode array insertion tool. It provides surgeons with consistent insertion speed and force. The system consists of a drive unit connected to a touch screen control console and foot pedal interface. The surgeon secures the base to the skull with two pre-loaded self-drilling bone screws. The drive unit is placed into the base and the adjustable drive head is coupled to a CI electrode. Before insertion begins, the surgeon s

Primary outcome measures

  • scalar translocation [Time frame: Postoperative standard of care CT (approximately at activation or 2 weeks)]
  • Angular Insertion depth [Time frame: Postoperative standard of care CT (approximately at activation or 2 weeks)]
Secondary outcome measures (1)
  • Impedance [Time frame: initial activation and at 3 and 6 months post CI]

Eligibility criteria

Inclusion criteria

  • Candidate for a cochlear implant according to CMS guidelines
  • Willingness to comply with all study requirements
  • Patent cochlea and normal cochlear anatomy, as confirmed by preoperative imaging
  • English speaking

Exclusion criteria

  • Medical or psychological conditions that contraindicate undergoing surgery
  • Ossification or any other cochlear anomaly that might prevent complete insertion of the electrode array.
  • Unrealistic expectations on the part of the candidate and/or candidate's family, regarding the possible benefits, risks, and limitations that are inherent to the surgical procedure(s) and prosthetic devices.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Randomized
Model
Parallel assignment
Masking
Open label
Primary purpose
Basic science

Study locations

United States · 1 center
  • University of Iowa Healthcare — Iowa City

Identifiers

NCT: NCT06951594 · 202210440

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗