Menu
Not yet recruiting NCT06924567

Radiographic Stability of Hip Prosthesis Prior to Revision Surgery

Observational Loosening, Prosthesis Hip Arthropathy

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Implant motion provocation CT.
Who it may be relevant to
Registry conditions: Loosening, Prosthesis, Hip Arthropathy. Basic parameters: No limits · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Denmark, Norway, Sweden
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

The Accuracy of CT-based Implant Movement for the Evaluation of Cup and Stem Stability, When Plain Radiography is Not Conclusive for Loosening, in Patients Scheduled for Revision Hip Arthroplasty. A Multicenter Study

Overview

The goal of this validation study is to compare the preoperative implant stability, assessed by Implant Movement Analysis (IMA), provocation dual CT scans, with the intraoperative stability evaluation in revision hip arthoplasty. The main question it aims to answer is: Does IMA reflect the intraoperative clinical evaluation of implant stability? Participants scheduled for revision hip arthoplasty will undergo IMA preoperativelly in addition to rutine clinical work up. During revision arthoplasty, a surgeon blinded to the IMA results will assess clinically the stability of the hip prosthesis. IMA will be compared with the intraoperative findings to assess IMAs sensitivity and specificity

Interventions

  • Diagnostic test Implant motion provocation CT
    Implant Movement Analysis. A low dose CT scan is performed with the hip fixed in external rotation. Then another low dose CT scan is performed with the hip fixed in internal rotation.The CT scans are then overimposed to each other and implant motion in relation to host bone is visualized,

Primary outcome measures

  • Cup and stem stability [Time frame: within 2 months month]

Eligibility criteria

Inclusion criteria

  • Patient scheduled for revision THA due to aseptic loosening.
  • One component (cup or stem) has no convincing loosening signs, based on the preoperative plain radiographs and clinical assessment by the attending surgeon.
  • Radiographs not older than 8 weeks prior to surgery.

Exclusion criteria

  • Both cup and stem have been preoperatively evaluated as loose
  • Instability with repeating dislocation of the THA
  • Non-aseptic revision surgery, based on preoperative work up.
  • The scheduled revisionsurgery is cancelled.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Sweden · 4 centers
  • Sahlgrenska University Hospital — Gothenburg
  • Hässleholm Hospital — Hässleholm
  • Danderyd Hospital — Stockholm
  • Akademiska University Hospital — Uppsala
Denmark · 1 center
  • Hvidovre Hospital — Copenhagen
Norway · 1 center
  • Oslo University Hospital — Oslo

Publications

  • Olivecrona H, Olivecrona L, Weidenhielm L, Noz ME, Kardos J, Maguire GQ Jr, Zeleznik MP, Aspelin P. A new technique for diagnosis of acetabular cup loosening using computed tomography: preliminary experience in 10 patients. Acta Orthop. 2008 Jun;79(3):346-53. doi: 10.1080/17453670710015247. PMID 18622838
  • Lovera D, Sandberg O, Mohaddes M, Gyllensten H. Cost-effectiveness of implant movement analysis in aseptic loosening after hip replacement: a health-economic model. Cost Eff Resour Alloc. 2023 Nov 20;21(1):88. doi: 10.1186/s12962-023-00498-w. PMID 37986000
  • Sandberg O, Carlsson S, Harbom E, Cappelen V, Tholen S, Olivecrona H, Wretenberg P. Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty. Acta Orthop. 2022 Oct 31;93:831-836. doi: 10.2340/17453674.2022.5240. PMID 36314542

Identifiers

NCT: NCT06924567 · 284803

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗