REgistry of Paclitaxel Coated Drug Eluting Balloon in All Comers PaTients
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- This is an observational study: the protocol does not assign a study treatment.
- Who it may be relevant to
- Registry conditions: CAD - Coronary Artery Disease. Basic parameters: from 18 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Center list to be confirmed — check the primary protocol.
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
REgistry of Paclitaxel Coated Drug Eluting Balloon in All Comers PaTients (REPEAT Registry)
Overview
A post marketing, observational , multi centre, prospective registry to assess safety and performance of the Drug Eluting Balloon in patients undergoing percutaneous coronary intervention. Rational : Although DEBs are generally considered safe, there remain many unanswered questions about DEB technology in a real-world population and only limited trial data from geographically or clinically diverse patient subgroups. To address some of the clinical and translational gaps in knowledge we thus plan a clinical registry to assess safety and performance of a novel design of a drug eluting A real-world, all-comers coronary artery disease (CAD) population undergoing percutaneous coronary intervention (PCI) and suitable for treatment with a Paclitaxel Coated Coronary Balloon Dilatation Catheter. Study Population - 500 Patients
Detailed description
Percutaneous coronary intervention (PCI) is a minimally invasive procedure treated as first line of treatment for symptomatic coronary artery disease (CAD). In 1977, Gruentzig performed the first balloon percutaneous transluminal coronary angioplasty (PTCA) but this was associated with acute dissection or elastic recoil and later restenosis (re-narrowing). Bare metal stents (BMS) were developed which helped address acute dissection or recoil but only modestly decreased the risk of restenosis (which still occurred in around 25% of people within six months).
Drug eluting stents (DES), coated with polymers which released drugs such as sirolimus or paclitaxel were then developed to reduce restenosis. Second-generation DES incorporating new metal platforms (changing from stainless steel to thinner strut metal alloys such as cobalt-chromium or platinum-chromium), new more biocompatible polymers, and new drugs such as Zotarolimus, Everolimus and Novolimus were associated with reduction in myocardial infarction (MI), target lesion revascularisation (TLR) and stent thombosis compared with first-generation DES.
However, even with second-generation DES, concerns remain regarding the risk of delayed healing, late stent thrombosis and in-stent restenosis (around 2% per year) and alteration of vascular physiology due to permanent caging by the stent. Hence, drug-eluting balloons (DEB), {also referred as Drug Coated Balloons (DCB)} were developed as a non-stent approach to circumvent some drawbacks of DES. Provided pre-dilatation does not induce excessive dissection or recoil requiring a stent, DEBs deliver rapid release and deposition of anti-restenotic drug in the vessel wall at the time of balloon inflation but without a permanent implant, thus enabling more rapid healing of the vessel, similar reduction in restenosis to DES but potentially reduced late complications.
Currently, DEBs are used in treating In-stent restenosis (ISR), bifurcation lesions, Ostial lesions, long \& large lesions, De novo of small vessel disease, complex coronary interventions, and high bleeding risk situations. Although DEBs are generally safe and non-inferior to other contemporary treatment procedure there are many unanswered questions about DEB technology in real world population. Geographical distribution of clinical trials or sample size and diversification is an important criterion to evaluate the safety and efficacy of the DEBs in real- world settings. The trend indicates fewer domestic trials for DEB. In lieu of the above clinical and translational gaps a registry is planned to assess safety and performance of the Drug Eluting Balloon in CAD patients.
Primary outcome measures
- Target Lesion failure [Time frame: 12 Month]
Secondary outcome measures (1)
- Major Adverse Cardiac Event (MACE) [Time frame: MACE at 1 year; Procedural & Device Success at Baseline]
Eligibility criteria
Inclusion criteria
- Age ≥ 18 years
- Patients with symptomatic coronary artery disease (including those with acute coronary syndromes or Chronic Coronary Syndromes) with either symptoms and/or ischaemia.
- The patient must be able to understand and provide informed consent and comply with all study procedures.
Coronary angiographic inclusion criteria:
- ≥70% target lesion stenosis in LAD, LCX or RCA (or branches) which after successful pre-dilatation\* has a residual stenosis ≤ 30% and no dissection of Type C or greater than (NHLBI guidelines)
\*pre-dilation permitted with SC or NC balloon catheter, cutting/scoring balloon, rotational/orbital atherectomy, or laser
- Target vessel reference diameter between 2.0 and 4.5 mm.
Exclusion criteria
- Left ventricular ejection fraction (LVEF) ≤ 30%
- Acute ST elevation MI (STEMI)
- Cardiogenic shock within 2 days prior to the index PCI.
- Known contraindication or hypersensitivity to paclitaxel, and/or to any anti-thrombotic and anti-platelet class of drugs
- Allergy to imaging contrast media which cannot be adequately pre-medicated.
- Patient undergoing planned surgery within 3 months with the necessity to stop dual antiplatelet therapy (DAPT).
- Patient is pregnant or breast feeding.
- Patient has received a heart transplant.
- Patient is unwilling or unable to give follow-up until study completion.
- Patient is currently participating in another trial.
- Life expectancy <1 year.
Angiographic exclusion criteria:
- Target lesion in the left main coronary artery.
- Flow limiting target vessel thrombus
- Vessel dissection requiring bailout stenting.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Observational model
- Cohort
Study locations
Center list to be confirmed — check the primary protocol.
Identifiers
NCT: NCT06899555 · TL/PMS/DEB/2024-01