Open Surgical, Modified Seldinger's and US Techniques for Jugular Central Line Insertion in Infants
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Open surgical cut down technique, Modified Seldinger's technique, Closed Ultrasound guided CVC insertion.
- Who it may be relevant to
- Registry conditions: Infants, Intensive Care Unit, Central Venous Catheterization. Basic parameters: 1 Hour — 18 months · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- Egypt
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Comparing Open Surgical, Modified Seldinger's and Ultrasound Guided Techniques for Jugular Central Line Insertion in Infants
Overview
The aim of this study was to compare the three approaches: open technique, modified Seldinger's technique and closed ultrasound-guided Central venous catheterization insertion for central line insertion in infancy as regards safety, success of cannulation, technique time, and preservation of the patency of the internal jugular vein.
Detailed description
Central venous catheterization is an essential technique in the intensive care units , for the administration of life-saving treatments including total parenteral nutrition, nutritional support, and intravenous medication. The internal jugular vein is often chosen because of its relatively larger size than the subclavian vein, lower risk of complications, and easy compressibility in case of bleeding. To facilitate Central venous catheterization, ultrasound guidance over anatomical guidance in closed techniques has been introduced bringing increased success rates, decreased catheterization times, and reduced complications.
Open surgical insertion is a common method of tunneled catheter implantation in the past, but the percutaneous approach has recently gained more popularity . The modified Seldinger's insertion technique is a catheter over guide wire technique, based on the original Seldinger's technique, and has not been widely adopted in Intensive care units. However, the modified Seldinger's technique has been successfully introduced into Intensive care units, and it is now used as the only technique for peripherally inserted central venous catheter insertion .
Central venous catheterization have become a mandatory part of clinical management in a variety of clinical circumstances in pediatric age groups. It allows resuscitation for intravascular fluid depletion and access for vasoactive medications and antibiotics, and it provides a means for hemodynamic monitoring and pacing. US guided closed technique is the updated use for insertion of IJV catheterization because it can both increase the success rate and decrease the complications related to Central venous catheterization placement
Interventions
- Device Open surgical cut down technique
The technique was performed following the descriptions of Farhadi et al. The infant was positioned in 30° (Trendelenburg's position), with a roll under his shoulders for neck extension and rotated to contralateral side of the surgical side to expose the incision site. Incision was done under sedation and pulse oximeter to monitor the oxygen saturation during the technique. Under complete aseptic technique, a small transverse incision 1cm was made on triangle bordered by the clavicle inferiorly - Device Modified Seldinger's technique
After proximal and distal control of the vein, a 24-G. cannula was carefully inserted directly to the internal jugular vein . The guidewire was inserted through the cannula, then the cannula was removed. A size 4-5 French short length catheter was passed and brought out through the guidewire, then the guidewire was removed. The wound was closed after the correct catheter position and good haemostasis was obtained; the area was covered with sterile dressing. - Device Closed Ultrasound guided CVC insertion
Ultrasound probe was connected to ultrasound unit and focused with ultrasonic gel and wrapped in a sterile plastic sheath. By wrapping the transducer in a sterile sheath, the probe place perpendicular to the long axis of the vessel, standard US two-dimensional (2D) imaging was used to visualize the vein in the short-axis view as a circle. Catheterization was performed under continuous dynamic observation of real-time 2D images. Insertion needle was advanced through the skin under US guidance int
Primary outcome measures
- success of cannulation [Time frame: 20 minutes]
Secondary outcome measures (1)
- Technique time [Time frame: within 30 minutes]
Eligibility criteria
Inclusion criteria
\- 1-patients needed Central venous catheterization insertion in the internal jugular vein for medical or surgical causes.
2- patients with age ranging from birth till two years
Exclusion criteria
- 1- femoral or subclavian Central venous catheterization insertion. 2- patients with thrombosed internal jugular vein . 3- patients with previous Central venous catheterization insertion. 4- those with malignant conditions
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Open label
- Primary purpose
- Prevention
Study locations
Egypt · 1 center
- Tanta University — Tanta
Publications
- Salah Eldin MM, Shehata SMK, Shehata MA, Elhaddad AA. Comparing open surgical, SELDINGER'S technique with surgical isolation of the vein and ultrasound guided techniques for jugular central line insertion in infants: a randomized clinical trial. BMC Surg. 2025 Jul 3;25(1):280. doi: 10.1186/s12893-025-02988-5. PMID 40611041
Identifiers
NCT: NCT06862492 · 36264MS38/1/23