Speech Perception of a Tonotopy-based Fitting for Cochlear Implant Recipients for 6 Months With Conventional Setting
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Tonotopic cochlear implant fitting FS4T.
- Who it may be relevant to
- Registry conditions: Sensorineural Hearing Loss, Bilateral. Basic parameters: from 18 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- France
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Contribution to Speech Perception of a Tonotopy-based Fitting for Patients With Cochlear Implants for 6 Months With a Conventional Setting: Prospective Cross-sectional Study
Overview
Main objective: Compare speech recognition in noise with tonotopic fitting (FS4T) and with conventional non-tonotopic fitting (FS4noT) in adult patients implanted for 6 months with a MED-EL cochlear implant with FS4noT strategy. Secondary objectives: Comparison of FS4noT and FS4T settings * for speech recognition in quiet * for subjective auditory spatial perception
Detailed description
Introduction: Cochlear implantation allows the rehabilitation of profound bilateral deafness, restoring speech perception and verbal communication when the traditional hearing aid no longer provides satisfactory hearing gain. A cochlear implant includes an electrode array and its functioning is based on the principle of cochlear tonotopy: each electrode encodes a frequency spectrum according to its position in the cochlea (high frequencies are assigned to the basal electrodes and low frequencies to the apical electrodes). The cochlear implant thus breaks down the frequency spectrum into a number of frequency bands via bandpass filters corresponding to the number of electrodes in the implant. During the fitting these bands can be modified by the audiologist. The fitting software developed by the manufacturers proposed a default fitting with a lower limit between 100 and 250 Hz according to the brands and an upper limit of about 8500 Hz. The frequency bands assigned to each electrode follow a logarithmic scale with the high frequencies for the basal electrodes and the low frequencies for the apical electrodes. This distribution takes into account the number of active electrodes but does not take into account the anatomy and the natural cochlear tonotopy specific to each patient. Several studies have analyzed the anatomical variations of the cochlear dimensions: size of the cochlea and the ratio between the contact surfaces of the electrodes with the cochlea are variable from one patient to another. The insertion depth during surgery is also variable due to parameters related to the patients as well as to the operator, which seems to impact the understanding of speech in noise. Mathematical algorithms have recently been developed to estimate the cochlear tonotopy of each patient from a CT scan assessment. CT imaging of the implanted ear combined with 3D reconstruction software, provides cochlear length measurements. Using this approach it is possible to measure the position of each electrode relative to the cochlear apex. Recently, MED-EL (Austria) has developed a new approach based on CT-scan and tuning of the frequencies associated with each electrode using anatomical information of position of the electrodes in the cochlea: this fitting is called anatomy-based fitting (ABF).
Recently \[Jiam et al. 2016, 2019\] showed that a frequency fitting based on the tonotopy of the electrodes allowed to obtain a better perception of pitch after 30 minutes of acclimatization. In a prospective randomized crossover study with a wearing time of 6 weeks on new cochlear implantees, Creff et al. (2023, 2024) obtained very significantly superior results with a tonotopic setting compared to a classic setting (HDCIS) for speech recognition tests in noise and for musical perception. However, even if the tonotopic setting appears particularly promising over a period of 6 weeks, it is possible that the difference diminishes over time (Mertens et al.,2021). Brain plasticity could partially or completely compensate for the mismatch after a few months/years of CI use (Svirsky et al. 2004; Reiss et al. 2007, 2014). However, this adaptation may remain incomplete or prolong the acclimatization period even after numerous rehabilitation sessions (Sagi et al. 2010; Svirsky et al. 2015; Tan et al. 2017; Dorman et al. 2022). Further studies on the use of tonotopy-based fitting and its effects on speech understanding, also in experienced CI users, are therefore needed.
Main objective:
Compare speech recognition in noise with tonotopic fitting (FS4T) and with conventional non-tonotopic fitting (FS4noT) in adult patients implanted for 6 months with a MED-EL cochlear implant with FS4noT strategy.
Secondary objectives:
Comparison of FS4noT and FS4T settings
* for speech recognition in quiet * for subjective auditory spatial perception
Plan of the study: It is a prospective open monocentric transversal study.
Interventions
- Other Tonotopic cochlear implant fitting FS4T
Comparison of FS4T and FS4noT
Primary outcome measures
- Speech recognition in noise [Time frame: 6 weeks after FS4T fitting]
Secondary outcome measures (2)
- Speech recognition in quiet [Time frame: 6 weeks after FS4T fitting]
- Subjective auditory spatial perception [Time frame: At FS4T fitting and 6 weeks after FS4T fitting]
Eligibility criteria
Inclusion criteria
- Adult patient (>= 18 years old) speaking French
- Patient who fulfils the criteria for cochlear implantation
Exclusion criteria
- retro-cochlear pathology: auditory neuropathy, vestibular schwannoma
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- N/A
- Model
- Single group
- Masking
- Open label
- Primary purpose
- Other
Study locations
France · 1 center
- CHU — Limoges
Identifiers
NCT: NCT06723262 · MEDEL_ABF6m_Limoges_study