Menu
Recruiting NCT06715293

A Study to Evaluate the Performance of a Wireless Optical Sensor Capsule in Detection of UGIB

No phase Interventional Melena Gastrointestinal Bleeding Hematemesis

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Hemopill, OGD.
Who it may be relevant to
Registry conditions: Melena, Gastrointestinal Bleeding, Hematemesis. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Hong Kong
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

A Prospective Study to Evaluate the Diagnostic Performance of a Wireless Optical Sensor Capsule in Detection of Upper Gastrointestinal Bleeding

Overview

Upper gastrointestinal bleeding (UGIB) is a common and potentially lethal medical emergency, which requires hospitalization and healthcare resources. Despite the changing epidemiology and advancement of endoscopic therapy in the recent decade, the all-cause mortality of UGIB remains high (\>2%). An accurate risk stratification is necessary to triage patients into low- or high-risk groups, in order to inform clinicians for the necessity and timing of urgent endoscopy. However, existing pre-endoscopy risk scores, such as the Glasgow-Blatchford score (GBS), Rockall score and AIMS65 score, are suboptimal in predicting relevant clinical outcomes. An alternative strategy for risk stratification is urgently warranted in patients with UGIB to guide the next step of management. In a pre-clinical study, the sensitivity and specificity of HemoPill® prototype were 95% and 87.5% respectively, when the sensors were positioned close to the bleeding point. Furthermore, several human clinical studies have proven the feasibility and accuracy of HemoPill® in healthy volunteers and patients with suspected UGIB. Capsule ingestion was well tolerated with no device-related adverse event or capsule retention. All patients with negative HI were found to have no active endoscopic bleeding (true negative, 100%, 17/17). In patients with bleeding \>20ml, true positive HI signals were detected (100%, 2/2) In a retrospective multi-center study, 61 patients with suspected UGIB were recruited to use HemoPill®. Among the capsule-positive cases, subsequent endoscopy confirmed active bleeding in 57% (20/35) of them. None of the capsule-negative patients rebled (0%, 0/25), which prevented unnecessary emergent endoscopy in 72% of them (18/25).

Detailed description

From December 2023 to February 2024, the investigator conducted a pilot study and screened 51 adult subjects with symptoms and signs of suspected UGIB in Prince of Wales Hospital. Among them, the investigator recruited 20 eligible subjects to receive HemoPill® examination before oesophago-gastro-duodenoscopy (OGD). The overall sensitivity was 80% with a negative predictive value of 87.5%. The area-under-receiver-operating-characteristic curve was 0.633.

The pilot data demonstrated a huge potential for this novel, non-invasive, easy-to-use device as UGIB screening in the real-world. A large-scale, prospective validation study will be conducted to evaluate the diagnostic performance of the new generation HemoPill® acute capsule in UGIB.

Interventions

  • Device Hemopill
    Hemopill will be swallowed to detect the presence of active bleeding in the upper GI tract
  • Procedure OGD
    OGD will be performed to compare the results of the hemopill

Primary outcome measures

  • Presence of active bleeding [Time frame: during OGD examination]
Secondary outcome measures (4)
  • Technical success rate [Time frame: during OGD examination]
  • Adverse event rate [Time frame: 30days post study procedure]
  • Capsule retention rate [Time frame: 30days post study procedure]
  • Time from Hemopill acute capsule ingestion to a positive HI signal [Time frame: during OGD examination]

Eligibility criteria

Inclusion criteria

  • Participants have symptoms and signs of suspected UGIB (melena, per rectal bleeding, coffee ground vomiting, prior hematemesis);
  • Participants will undergo urgent or elective OGD within 24 hours from recruitment;
  • Written consent obtained.

Exclusion criteria

  • Contraindications for OGD (e.g. respiratory failure, suspected perforation);
  • Contraindications for capsule endoscopy (e.g. known gastrointestinal obstruction or stricture, severe dysphagia, impaired consciousness);
  • Cardiac pacemaker or implanted electromedical devices;
  • History of gastrectomy or bowel resection;
  • Ongoing fresh hematemesis requiring emergent endoscopy;
  • Unstable hemodynamics despite adequate resuscitation requiring emergent endoscopy (i.e. systolic blood pressure <100mmHg or pulse rate >100 per minute);
  • Advanced comorbidities (defined as American Society of Anesthesiologists grade 4 or above);
  • Pregnancy.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Non-randomized
Model
Single group
Masking
Single blind
Primary purpose
Diagnostic

Study locations

Hong Kong · 1 center
  • Prince of Wales Hospital — Shatin

Identifiers

NCT: NCT06715293 · 2024.181

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗