Registry of PHAcoemulsification for Cataract Surgery
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- This is an observational study: the protocol does not assign a study treatment.
- Who it may be relevant to
- Registry conditions: Cataract. Basic parameters: No limits · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- France
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Overview
Cataracts cause vision loss due to opacities in the lens. Cataract surgery is performed by emulsifying the nucleus of the lens. A phacoemulsifier is the machine used to deliver ultrasonic energy in the eye to fragment the lens and aspirate the debris. In contrast to the large number of cataract procedures performed worldwide, there is surprisingly scarce data regarding the intraoperative parameters used during phacoemulsification. As new technologies are made available to surgeons, this impedes a large-scale analysis of the benefits of the advances in phacoemulsifiers. The investigators aim to establish a nationwide registry with a database of intraoperative data recorded during the cataract procedures performed with the Centurion phacoemulsifier. The data collected would encompass all parameters recorded in the phacoemusifiers' logs, such as the energy delivered in the eye (longitudinal, torsional and other), US time, BSS volume, duration of the procedure, surgeon settings and others. The objective will be to capture data from at least 100,000 procedures/year.
Detailed description
A nationwide registry will be established with a database of intraoperative data recorded during the cataract procedures performed with the Centurion phacoemulsifiers. The following intraoperative parameters used during the cataract surgery will be recorded and analyzed:
Primary endpoint: Ultrasound time (US time)
Exploratory endpoints:
* CDE : Cumulated dissipated Energy * Total surgery time * BBS volume * Torsional and longitudinal energy * IOP settings * Vacuum settings Procedures performed with the Active Sentry module - where a pressure sensor is built in the phacoemulsifier handpiece will be compared to other to procedures performed without this module.
Data will be collected and analyzed from Centurions cases log extracted from at least 200 Centurions installed in France. Parameter and settings will be retrospectively analyzed.
A direct extraction of data from the machines will be processed for the analyses. No patient demographic data will be recorded.
The objective will be to capture data from at least 100,000 procedures and to run data analyses on a nationwide scale.
The database will serve as a basis to assess the technological advances aimed at reducing the amount of energy delivered in the eye, the duration of ultrasound use and overall the duration of procedures.
Primary outcome measures
- Description of intraoperative parameters during cataract surgery when using Active Sentry [Time frame: time of the surgery]
Eligibility criteria
Inclusion criteria
\- All procedures recorded in Centurions (200 machines).
Exclusion criteria
- Opposition of the center to data collection.
- Complicated surgery (e.g. anterior vitrectomy) identified as such in the event log
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Observational model
- Other
Study locations
France · 1 center
- Ophthalmology department - Cochin Hospital — Paris
Identifiers
NCT: NCT06659419 · APHP240817