Menu
Not yet recruiting NCT06615583

A Novel Adaptive Anastomotic Technique for Left-sided Colonic Resection

No phase Interventional Colon Neoplasm

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Surgical device.
Who it may be relevant to
Registry conditions: Colon Neoplasm. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Italy
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

A Novel Adaptive Anastomotic Technique for Left-sided Colonic and Rectal Resection: a Pilot, Single-center, Prospective, Case-series Study

Overview

The goal of this pilot clinical trial is provide preminary evidence of the effectiveness of the C-REX device, developed by CarpoNovum AB, in preventing anastomotic leak and improving anastomosis healing after sigmoid or high rectal resection in patients with colon neoplasia. The primary aim of the study is to evaluate the rate of anastomotic leak in patients receiving the study device within 90 days from the surgical procedure.

Detailed description

Despite technological advancements, the rate of anastomotic leak after left colon and high rectal resection remains high, around 20%. The device C-REX, developed by CarpoNovum, may help the anastomosis construction and promote its healing. This may lead to reduced anastomotic leak rate and severity. This study aims to collect preliminary evidence on the effectiveness of C-REX to develop a future larger multicentric trial. This pilot study will collect preliminary data on the rate and severity of 90-day anastomotic leak in patients receiving the C-REX device.

Interventions

  • Device Surgical device
    The C-REX device consists of an invasive surgical part, including two anastomotic rings, and surgical instruments for assisting the placement of the anastomotic ring to intestine. The rings are loosen from the inside of the intestinal wall and expelled with faeces per rectum once the anastomosis is healed in approximately ten days.

Primary outcome measures

  • Anastomotic leak rate [Time frame: 90 days after surgery]
Secondary outcome measures (4)
  • Intraoperative anastomotic failures [Time frame: Intraoperative]
  • Time of anastomosis construction [Time frame: Intraoperative]
  • Time of C-REX evacuation [Time frame: Ten days after surgery]
  • Anastomosis stenosis incidence rate [Time frame: 90 days after surgery]

Eligibility criteria

Inclusion criteria

  • Patients aged equal or more than 18 years old, both men and women.
  • Patients with a proven diagnosis of sigmoid colon or high rectal tumors requiring anterior rectal resection as procedure of choice (colorectal cancer or benign polyps), as confirmed by radiological and histological exams.
  • Patient indicated to minimally invasive or open sigmoid or high rectal resection.

Exclusion criteria

  • Patients with pre-existing health conditions requiring surgery, such as intestinal obstruction or perforation, local or systemic infections, peritonitis, or intestinal ischemia. Patients with intraoperative evidence of any of these conditions will be withdrawn from the study.
  • Patients with preoperative evidence of distal metastasis. Patients with intraoperative evidence of distal metastasis or peritoneal carcinosis will be withdrawn from the study.
  • Patients with documented intestinal or anal stenosis or other obstructions distal to the anastomosis. Patients with intraoperative evidence of intestinal or anal stenosis will be withdrawn from the study.
  • Patients who received radiation therapy to organs in abdomen or pelvis unrelated to current colorectal condition.
  • Patients who are unable or received contraindication for the preoperative mechanical preparation. Patients with a preoperative evidence or suspicion of incomplete colon cleansing will be withdrawn from the study.
  • Patients indicated to defunctioning stoma. Patients requiring diverting stoma as for intraoperative indication will be withdrawn from the study.
  • Patients with an anastomosis in rectum below the peritoneal reflection and/or another procedure of choice than high anterior resection.
  • Any condition that, in the opinion of the investigator, may interfere with the study conduction. In particular, any condition which can cause significant alteration of colonic wall thickness such as chronic and repeated infection which may impair the use of C-REX.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
N/A
Model
Single group
Masking
Open label
Primary purpose
Treatment

Study locations

Italy · 1 center
  • IRCCS Humanitas Research Hospital — Rozzano

Identifiers

NCT: NCT06615583 · CHR1-2024-102

Primary sources (government registries)