Menu
Recruiting NCT06581016

Performance Characteristics and Technical Outcomes of Single-use vs. Reusable Gastroscopes Evaluated in the OR

No phase Interventional Upper Gastrointestinal Disorder

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Ambu aScope Gastro, Ambu aScope Gastro Large, Diagnostic gastroscopes, Olympus, Therapeutic gastroscopes, Olympus.
Who it may be relevant to
Registry conditions: Upper Gastrointestinal Disorder. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Denmark
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Performance Characteristics and Technical Outcomes of Single-use Versus Reusable Gastroscopes Evaluated in the Operating Room in Acute, Subacute and Elective Patients

Overview

The goal of this clinical trial is to investigate whether single-use gastroscopes are as good as reusable gastroscopes when used in the operation theater in all patients where gastroscopy in the operation theater is indicated. The main question it aims to answer is: \- Is the technical success and performance characteristics the same for single-use and reusable gastroscopies? Researchers will compare single-use gastroscopes with reusable gastroscopes to see if the technical success and performance characteristics are the same in the to groups. Participants will in the first period have gastroscopy with a single-use gastroscope. In the second period participants will have gastroscopy with a reusable gastroscope.

Interventions

  • Device Ambu aScope Gastro
    CE-marked single-use gastroscopes from Ambu are used in the single-use group.
  • Device Ambu aScope Gastro Large
    CE-marked single-use gastroscopes from Ambu are used in the single-use group.
  • Device Diagnostic gastroscopes, Olympus
    Reusable gastroscopes from Olympus are used in the reusable group.
  • Device Therapeutic gastroscopes, Olympus
    Reusable gastroscopes from Olympus are used in the reusable group.

Primary outcome measures

  • Technical success of single-use gastroscopes vs reusable gastroscopes [Time frame: From admission to discharge, up to 3 months]
Secondary outcome measures (9)
  • Complications [Time frame: 24 hours and 72 hours follow-up after procedure]
  • 30th day mortality [Time frame: 30 days]
  • Endoscopist's rating of gastroscope [Time frame: Right after procedure]
  • Duration of procedure [Time frame: During the procedure]
  • Time from procedure to discharge [Time frame: From procedure to discharge, up to 3 months]
  • Success of specific therapeutic procedures [Time frame: During the procedure]
  • Need of new gastroscopy [Time frame: During admission, up to 3 months]
  • Readmission [Time frame: 30 days after procedure]
  • Sufficient ability to target the biopsy if taken [Time frame: During procedure]

Eligibility criteria

Inclusion criteria

  • Acute, subacute or elective gastroscopies in the operating theater
  • Age ≥ 18 years

Exclusion criteria

  • None

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Non-randomized
Model
Parallel assignment
Masking
Open label
Primary purpose
Treatment

Study locations

Denmark · 1 center
  • Zealand University Hospital — Køge

Publications

  • Turk DJ, Kozarek RA, Botoman VA, Patterson DJ, Ball TJ. Disposable endoscopic biopsy forceps: comparison with standard forceps of sample size and adequacy of specimen. J Clin Gastroenterol. 1991 Feb;13(1):76-8. PMID 2007750
  • Forbes N, Elmunzer BJ, Allain T, Parkins MD, Sheth PM, Waddell BJ, Du K, Douchant K, Oladipo O, Saleem A, Cartwright S, Chau M, Howarth M, McKay J, Nashad T, Ruan Y, Bishay K, Gonzalez-Moreno E, Meng ZW, Bass S, Bechara R, Cole MJ, Jalink DW, Mohamed R, Turbide C, Belletrutti PJ, Kayal A, Kumar PR, Hilsden RJ, Buret AG, Hookey L, Heitman SJ. Effect of Disposable Elevator Cap Duodenoscopes on Persi PMID 36689215
  • Ross AS, Bruno MJ, Kozarek RA, Petersen BT, Pleskow DK, Sejpal DV, Slivka A, Moore D, Panduro K, Peetermans JA, Insull J, Rousseau MJ, Tirrell GP, Muthusamy VR. Novel single-use duodenoscope compared with 3 models of reusable duodenoscopes for ERCP: a randomized bench-model comparison. Gastrointest Endosc. 2020 Feb;91(2):396-403. doi: 10.1016/j.gie.2019.08.032. Epub 2019 Nov 1. PMID 31679738
  • Bruno MJ, Beyna T, Carr-Locke D, Chahal P, Costamagna G, Devereaux B, Giovannini M, Goenka MK, Khor C, Lau J, May G, Muthusamy VR, Patel S, Petersen BT, Pleskow DK, Raijman I, Reddy DN, Repici A, Ross AS, Sejpal DV, Sherman S, Siddiqui UD, Ziady C, Peetermans JA, Rousseau MJ, Slivka A; EXALT Single-use Duodenoscope Study Group. Global prospective case series of ERCPs using a single-use duodenoscop PMID 37463599
  • Ramai D, Smit E, Kani HT, Papaefthymiou A, Warner L, Chandan S, Dhindsa B, Facciorusso A, Gkolfakis P, Ofosu A, Barakat M, Adler DG. Cannulation rates and technical performance evaluation of commericially available single-use duodenoscopes for endoscopic retrograde cholangiopancreatography: A systematic review and meta-analysis. Dig Liver Dis. 2024 Jan;56(1):123-129. doi: 10.1016/j.dld.2023.02.022 PMID 37003844
  • Luo X, Ji M, Zhang S, Chen X, Zong Y, Zhang X, Hu H, Hao X, Shao L, Sun C, Shi H, Wang J, Wang B, Li P. Disposable versus reusable gastroscopes: a prospective randomized noninferiority trial. Gastrointest Endosc. 2022 Aug;96(2):250-261. doi: 10.1016/j.gie.2022.03.024. Epub 2022 Apr 4. PMID 35381230
  • Li DF, Shi RY, Tian YH, Xu ZL, Zhou YS, Sun XJ, Cai JW, Fang YY, Peng H, Wang JM, Dong T, Cai YD, Yao J, Wang LS. The feasibility and safety of disposable endoscope vs. conventional endoscope for upper gastrointestinal tract examination: a multicenter, randomized, parallel, non-inferiority trial. Z Gastroenterol. 2022 Sep;60(9):1314-1319. doi: 10.1055/a-1555-0568. Epub 2021 Nov 12. PMID 34768288
  • van der Ploeg K, de Jonge PJF, Lammers WJ, Koch AD, Vos MC, Paulsen V, Aabakken L, Bruno M. Performance of a single-use gastroscope for esophagogastroduodenoscopy: Prospective evaluation. Endosc Int Open. 2024 Mar 18;12(3):E428-E434. doi: 10.1055/a-2271-2303. eCollection 2024 Mar. PMID 38504741

Identifiers

NCT: NCT06581016 · SUSUES_COP

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗