Recruiting NCT06522867

Evaluation of Intraocular Pressure Following a Vitreoretinal Surgery Using Goldmann Applanation Tonometry, Icare and Accupen

No phase Interventional Intraocular Pressure

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Intraocular pressure measure.
Who it may be relevant to
Registry conditions: Intraocular Pressure. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Canada
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Reliability Evaluation of Intraocular Pressure At Day 1 Following Vitreoretinal Surgery, Comparing Goldmann Applanation Tonometry (Gold Standard) to Icare and Accupen

Overview

The goal of this prospective controlled study is to measure the reliability of two intraocular pressure (IOP)-measuring instruments in comparison to the gold standard, Goldmann applanation tonometry (GAT) following vitreo-retinal surgery. The main question the current study aims to answer is: are Icare and Accupen as accurate as GAT in measuring IOP one day post eye surgery? Participants in this study will have their IOP measured by the three different instruments one day post-surgery.

Detailed description

Goldmann applanation tonometry (GAT), used since 1948, is the reference technique for measuring intraocular pressure (IOP) in both healthy patients and those suffering from glaucoma or other eye disorders. However, the use of GAT requires the topical application of fluorescein, local anesthesia, and direct contact with the cornea. In addition to its lack of portability, these characteristics of GAT quickly led clinicians to try to find simpler, less cumbersome, but just as reliable techniques to measure IOP. Among the techniques developed to potentially replace GAT, two portable techniques are particularly easy to use: rebound tonometry (Icare) and portable applanation tonometry (Accupen). Before these techniques are universally and interchangeably used with GAT, their reliability and accuracy must be measured. The majority of studies have evaluated these techniques in glaucomatous or healthy eyes, presenting mixed but promising results. However, only one recent study has evaluated the validity of the two techniques (Icare and TonoPen) in a post-operative context of vitreo-retinal surgery. More data is therefore necessary to come to a definitive conclusion regarding the reliability of Icare and Accupen.

The objective of this study is therefore to determine whether the IOP measured by Accupen and/or Icare is as accurate as that taken by GAT in patients who have undergone vitreo-retinal surgery.

To answer this question, this project will be a prospective controlled study of 67 patients who have undergone vitreo-retinal surgery and who will have their intraocular pressure taken 1 day post-operatively by the 3 instruments mentioned above, in a randomized order. At their 1-day post-operative visit, an ocular medical history will be taken, including the preoperative diagnosis and the type of surgery performed. A resident in ophthalmology at Laval University, will take a series of 2 intraocular pressures with these 3 devices: GAT, Icare, and Accupen and will average for each group.

The project research hypothesis would be that the taking of intraocular pressure by Icare and/or Accupen is as valid as that taken by Goldman's applanation tonometry.

Interventions

  • Other Intraocular pressure measure
    The intraocular pressure of the subjects using either the Goldmann applanation tonometer, Icare or Accupen. The order of the measure is randomized.

Primary outcome measures

  • Absence of difference between intracular pressure measured by devices [Time frame: at the post-operative visit (1 day after surgery)]
Secondary outcome measures (1)
  • Reliability and validity of devices at all intracular pressure level [Time frame: at the post-operative visit (1 day after surgery)]

Eligibility criteria

Inclusion criteria

  • Age ≥ 18
  • Received a vitreoretinal surgery

Exclusion criteria

  • Corneal dystrophy
  • Corneal surgery (penetrating keratoplasty, DSAEK/DMEK less than 6 months, radial keratotomy)
  • Irregular corneal surface
  • Active corneal ulcer
  • Active epithelial deficit
  • Central corneal scarring
  • A history of scleral buckle

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
N/A
Model
Single group
Masking
Open label
Primary purpose
Other