Project Mountain - Comparing SpO2 and SaO2 for Accuracy
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: SaO2 Sampling.
- Who it may be relevant to
- Registry conditions: SpO2, Nasal Alar Collapse, Bilateral, Oxygen, Measurement. Basic parameters: No limits · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- United States
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Philips FAST picoSAT Convenience Sampling for Clinical Performance in Neonate, Infant, and Pediatric Patients
Overview
The main goal of this study is to look at the performance of the neonatal, infant, and pediatric Philips SpO2 sensors with the Philips FAST Pulse Oximetry technology. Oxygen saturation measurements (SpO2) will be obtained via pulse oximetry and invasive arterial oxygen measurements (SaO2) will be obtained via arterial blood samples as part of your clinical care and assessed by co-oximetry. The study will aim to enroll a diverse population to help us understand the impact of skin pigmentation.
Detailed description
This is a prospective, multi-center, multi-phase, unblinded, non-randomized. self-controlled, observational study. All data analyses specified below will be calculated and summarized by each of SpO2 sensors under test. Demographics and baseline characteristics, including sex assigned at birth, age, ethnicity, race, baseline height, baseline weight, BMI, skin pigmentation and sensor application site measurements will be summarized with descriptive statistics using the analysis set.
Interventions
- Device SaO2 Sampling
CO-Oximetry analysis of arterial blood samples
Primary outcome measures
- To observed accuracy expressed in ARMS of SpO2 measurements obtained from neonatal, infant, and pediatric sensors with the Philips FAST Pulse Oximetry technology within the range of 70-100% in comparison to the SaO2 as ground truth. [Time frame: through study completion, an average of 8 months]
Secondary outcome measures (2)
- Secondary Endpoint -Non-disparate bias with consideration to skin pigmentation for each neonatal, infant, and pediatric SpO2 sensor under test with the Philips FAST Pulse Oximetry technology. [Time frame: through study completion, an average of 8 months]
- Secondary Endpoint- Proportion of paired SaO2 and SpO2 readings in which occult hypoxemia (i.e., SaO2 <88% with SpO2 ≥92%) is identified among patients within the broad categories of light, medium, and dark pigmentation. [Time frame: through study completion, an average of 8 months]
Eligibility criteria
Inclusion criteria
- Subject aged 18 years or older or parent/legal guardian of subject aged less than 18 years, willing and able to understand and provide written informed consent/assent.
- Weight and/or age within intended use of at least one SpO2 sensor under test at time of enrollment.
- Willing and able to wear study devices in addition to SoC devices and during SoC procedures.
- In-patient within a neonatal or pediatric intensive care unit (e.g. NICU, PICU, PCICU).
- Has arterial access and ability to have arterial blood samples drawn as part of their SoC and analyzed by CO-Oximetry.
Exclusion criteria
- Known pregnancy or lactating females (self-reported)
- Injury, wounds, physical malformation, hyperkeratosis, or compromised/non-intact skin at sensor application site (i.e. fingers, toes, hands, feet, ears, nasal ala). Note: Certain malformations may be allowed if determined it would not affect application of sensor with the pulse oximetry system.
- Self-reported severe contact allergies to standard adhesives or other materials found in pulse oximetry sensors. Note: Subject may be considered eligible if subject can wear non-adhesive sensor.
- Unwillingness or inability to remove nail polish or artificial nails from sensor application site.
- Nail fungus on sensor application site.
- Wearing and unable to remove jewelry from sensor application site.
- Dye injection within 48 hours of enrollment.
- Known dysfunctional hemoglobin levels (COHb >3%, MetHb >2%, and ctHb <10g/dl)
- Undergoing phototherapy for neonatal hyperbilirubinemia during arterial blood sampling
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: Yes
Study design
- Observational model
- Other
Study locations
United States · 5 centers
- Phoenix Children's — Phoenix
- University of Nebraska Medical Center — Omaha
- Duke University Medical Center — Durham
- Medical University of South Carolina — Charleston
- Baylor College of Medicine — Houston
Identifiers
NCT: NCT06372106 · MA_PM_Mountain_2022_11496