Menu
Recruiting NCT06333327

Multicenter Registry of Atrial Fibrillation Ablation With Radiofrequency Balloon Catheter

Observational Atrial Fibrillation

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Pulmonary vein isolation with the multielectrode radiofrequency balloon catheter.
Who it may be relevant to
Registry conditions: Atrial Fibrillation. Basic parameters: 18 years — 85 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Belgium
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Multielectrode Radiofrequency Balloon for Atrial Fibrillation Catheter Ablation: A Multicenter Real-World Experience

Overview

All consecutive patients with paroxysmal or persistent atrial fibrillation undergoing pulmonary vein isolation with the radiofrequency balloon catheter (RFB) "Heliostar" (Biosense Webster) will be included in a multicenter observational registry. The aim of the study is to assess the safety and arrhythmic outcome of atrial fibrillation ablation with the RFB in a real-world setting.

Detailed description

All consecutive atrial fibrillation patients undergoing pulmonary vein isolation (PVI) with the novel radiofrequency balloon catheter (RFB) "Heliostar" (Biosense Webster) will be prospectively included in a multicenter observational registry.

PVI with the RFB will be performed as previously described. Briefly, after optimal RFB positioning, confirmed through the correct alignment between the RFB and the pulmonary vein and sufficient electrode-tissue contact, ablation is performed in temperature-controlled mode with unipolar radiofrequency energy. Typically, \>2 posterior electrodes are identified on the RFB. The power setting is 15 W and the target electrode temperature is 55° C. The same energy is simultaneously delivered to all electrodes, with a duration of 15-20 s for the posterior and 45-60 s for the non-posterior electrodes. During ablation, pulmonary vein potentials are monitored on the circular diagnostic catheter to evaluate real-time isolation. In the case of pulmonary vein acute reconnection, additional applications are delivered to achieve durable PVI. An esophageal temperature probe will be used to monitor any increase in esophageal temperature.

Follow-up will be performed according to each standard institutional protocol.

Safety endpoints include any major periprocedural complications \[e.g. death, atrioesophageal fistula, stroke/transient ischaemic attack, pericardial effusion/tamponade with/without surgical treatment, myocardial infarction, and persistent phrenic palsy\] occurring within 7 days post-procedure (except for atrioesophageal fistula). Minor complications will also be reported, including vascular access complications requiring treatment, pericarditis, and transient phrenic palsy.

Efficacy outcome is defined as arrhythmia-free survival during the follow-up. Arrhythmia recurrence is defined as any atrial tachyarrhythmias ≥30 s after a 90-day post-ablation blanking period.

Interventions

  • Device Pulmonary vein isolation with the multielectrode radiofrequency balloon catheter
    Pulmonary vein isolation with the multielectrode radiofrequency balloon catheter

Primary outcome measures

  • Atrial arrhythmia recurrence after ablation [Time frame: After 3 months post-ablation.]
  • Procedural safety [Time frame: Up to 7 days post-procedure (except for atrioesophageal fistula or pulmonary vein stenosis)]

Eligibility criteria

Inclusion criteria

  • symptomatic atrial fibrillation with indication to catheter ablation

Exclusion criteria

  • age <18 years old
  • pregnancy
  • any contraindications to catheter ablation

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Belgium · 1 center
  • UZ Brussel Heart Rhythm Management Center — Brussels

Identifiers

NCT: NCT06333327 · 1432022000278

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗