Mechanisms of Ultrasound Neuromodulation Effects in Diabetes
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Ultrasound, OGTT with unlabeled glucose and liver NMR, OGTT with carbon-13 labeled glucose and liver NMR, CGM glucose reading.
- Who it may be relevant to
- Registry conditions: Insulin Sensitivity. Basic parameters: 18 years — 80 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- United States
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Overview
This study aims to evaluate the effect of hepatic ultrasound treatment on changes from baseline in whole-body insulin sensitivity during a hyperinsulinemic, euglycemic clamp (HE Clamp).
Detailed description
Drop-outs will be replaced; data will be used as much as can be. Subjects will undergo a Screening visit to assess eligibility and will then be scheduled to undergo 2 outpatient US treatment visits.
On day three subjects first undergo a third ultrasound session and then will either undergo Oral Glucose Tolerance Test (OGTT) with carbon13 (13C-glucose) tracer administration and subsequent NMR spectroscopy OR if enrolled into the HEC study arm will undergo euglycemic clamp testing. Following these procedures there will be an approximately two-week follow-up observational Period (with CGM). A two-week washout period will be followed by another cycle of the same procedures of either OGTT/NMR or HEC study, respectively.
Interventions
- Device Ultrasound
The General Electric LOGIQ E10 ultrasound pulsed doppler imaging system and C1-6-D XDclear abdominal curvilinear probe will be used to administer ultrasound. - Diagnostic test OGTT with unlabeled glucose and liver NMR
Subjects will undergo an OGTT with unlabeled glucose to measure liver glycogen concentration by NMR spectroscopy. - Diagnostic test OGTT with carbon-13 labeled glucose and liver NMR
Subjects will undergo an OGTT with carbon-13 labeled glucose to measure liver glycogen synthesis rate by NMR spectroscopy. - Diagnostic test CGM glucose reading
A continuous glucose monitor (CGM) will be collecting glucose level changes over a 10-14day time period after the ultrasound. - Diagnostic test HEC - Hyperinsulinemic-Euglycemic-Clamp
A constant i.v. insulin and variable glucose infusion will be used to determine insulin sensitivity of study participants.
Primary outcome measures
- Insulin Sensitivity [Time frame: Measured during HE clamp.]
- Glucose disposal rate [Time frame: Measured during HE clamp.]
- Glucose metabolic clearance rate [Time frame: Measured during HE clamp.]
Secondary outcome measures (6)
- Absolute glycogen level [Time frame: during glucose tolerance testing (for 180 minutes).]
- Glycogen synthesis rates [Time frame: during glucose tolerance testing (for 180 minutes).]
- Change from baseline in blood glucose (BG) time spent in defined glucose ranges [Time frame: 1 week]
- Average daily glucose [Time frame: 1 week]
- Low blood glucose index (LBGI) [Time frame: 1 week]
- High blood glucose index (HBGI) [Time frame: 1 week]
Eligibility criteria
Inclusion criteria
- Type 2 diabetic (T2D) subjects must be aged 18-80 and must be able to provide written informed consent
- All subjects must have had T2D for at least 3 months prior to study enrollment. All subjects must be either on diet and exercise or oral antidiabetic agents alone, not on insulin or any form of insulin or GLP-1 receptor agonists.
- Subjects must demonstrate:
- A past medical history of abnormal glucose control and carry a diagnosis of T2D according to current ADA criteria:
- A fasting plasma glucose (FPG) level of 126 mg/dL (7.0 mmol/L) or higher, or
- A 2-hour plasma glucose level of 200 mg/dL (11.1 mmol/L) or higher during a 75-g oral glucose tolerance test (OGTT), or
- A random plasma glucose of 200 mg/dL (11.1 mmol/L) or higher in a patient with classic symptoms of hyperglycemia or hyperglycemic crisis or
- A hemoglobin A1c (HbA1c) level of 6.5% or higher.
- Be willing to carry a continuous glucose monitor for at least 10 days.
- Be willing to follow all required instructions by study personnel and appear for the required laboratory assessments, including euglycemic clamps and OGTT.
Exclusion criteria
- BMI >40kg/m2.
- Untreated proliferative retinopathy
- Creatinine clearance < 60 ml/min/1.73 m2.
- Serum creatinine ≥1.5 mg/dL
- Positive pregnancy test, or presently breast-feeding, or failure to follow effective contraceptive measures
- Active infection including hepatitis C, hepatitis B, HIV,
- Any history of Active alcohol abuse
- History of non-adherence to prescribed regimens
- Baseline Hgb < 10.5 g/dL in females, or < 13 g/dL in males
- History of coagulopathy or medical condition requiring long-term anticoagulant therapy (low-dose aspirin treatment is allowed)
- Co-existing cardiac disease with active medication titration. Patients on stable meds without active cardiac complications permitted.
- Liver function tests outside of 3xUL of normal range
- GI disorders potentially interfering with the ability to absorb oral medications and h/o upper GI surgery that might have changed anatomy in the target areas.
- Any medical condition or medication that, in the opinion of the investigators, will interfere with the safe completion of the study or study outcomes.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Single blind
- Primary purpose
- Other
Study locations
United States · 1 center
- Yale School of Medicine — New Haven
Identifiers
NCT: NCT06042517 · 2000034954 · 1R01DK131127-01A1