Menu
Recruiting NCT05679232

Hydrogel Coating to Reduce Post-surgical Infection After Joint Arthroplasty

No phase Interventional Arthritis Traumatic Arthritis Avascular Necrosis

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: Hydrogel coating, Control.
Who it may be relevant to
Registry conditions: Arthritis, Traumatic Arthritis, Avascular Necrosis. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Austria
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Randomized, Controlled, Monocentric, Feasibility Clinical Investigation to Assess the Safety and Preliminary Clinical Performance of a Hydrogel Coating to Reduce Post-surgical Infection After Joint Arthroplasty

Overview

The goal of this randomized, controlled, monocentric, single-blind, 2-arm, feasibility clinical investigation is to evaluate the safety of MectaShield hydrogel coating and to capture its preliminary clinical performance in the prevention of early peri-prosthetic joint infection (PJI) in patients undergoing cementless revision hip arthroplasty. The main questions it aims to answer are: * demonstrate that the hydrogel coating MectaShield does not interfere with primary stability; * evaluate clinical and functional outcomes, the rate of PJI and possible adverse events. Participants will undergo cementless revision hip arthroplasty; during surgery MectaShield hydrogel coating is applied on orthopaedic implants' surfaces (femoral stem and, if revised, acetabular cup) as a protective barrier for the prevention of bacterial adhesion. Surgery and follow-up are completed as per local standard practice. Stability will be assessed radiologically, while functional outcomes and PJI will be monitored by HOOS-PS, ASESPIS scores and according to the consensus document presented by European Society of Radiology (ESRa), the European Association of Nuclear Medicine (EANM), the European Bone and Joint Infection Society (EBJIS), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID). Researchers will compare the results of the treatment group with those from a control group receiving cementless revision hip arthroplasty without the application of MectaShiled hydrogel coating.

Detailed description

Peri-prosthetic joint infection (PJI) is among the first three reasons for joint replacement failure. PJI is a serious condition that may lead to repeated surgical interventions, prolonged hospitalization, high costs, and significant morbidity, although low mortality. To address this concern, antibacterial coating of implants has been proposed, as the adherence of the microorganisms to the implant, forming a biofilm, plays a strategic role in the pathogenesis of PJI. MectaShield (Medacta International SA) is a novel resorbable hydrogel coating intended to be spread on orthopaedic implants' surfaces as a protective barrier for the prevention of PJI. The study aims to evaluate the safety of MectaShield and to capture its preliminary clinical performance in the prevention of early PJI in patients undergoing cementless revision hip arthroplasty.

Patients suitable to receive MectaShield for cementless revision hip arthroplasty will be invited to take part to the study during the preoperative visit. Follow-up is performed after 3 and 12 months. Data collection includes clinical and functional data for preoperative and postoperative assessments, as well as intraoperative details, adverse events and device deficiencies. Patients will be randomized 1:1 in 2 groups:

* Control (no MectaShield) * MectaShield hydrogel coating (+ antibiotic)

The primary objective is to demonstrate that MectaShield hydrogel coating does not interfere with early primary stability at 3 months of follow-up

Secondary objectives are:

1. To demonstrate that MectaShield does not interfere with primary stability at 12 months of follow-up 2. To evaluate clinical and functional outcomes at 3 and 12 months of follow-up 3. To evaluate the rate of PJI at 3 and 12 months of follow-up 4. To evaluate the occurrence of adverse events and device deficiencies

Interventions

  • Device Hydrogel coating
    hydrogel coating applied to implant's surfaces during cementless hip revision arthroplasty
  • Procedure Control
    standard cementless hip revision arthroplasty

Primary outcome measures

  • Stem subsidence [Time frame: 3 months follow up]
Secondary outcome measures (9)
  • Stem subsidence [Time frame: 12 months follow up]
  • Presence of radiolucent zones in the femur [Time frame: 3 and 12 months follow up]
  • Cup migration (if revised) [Time frame: 3 and 12 months follow up]
  • Cup orientation (if revised) [Time frame: 3 and 12 months follow up]
  • Presence of radiolucent lines in the acetabular cup (if revised) [Time frame: 3 and 12 months follow up]
  • Clinical and functional outcomes [Time frame: 3 and 12 months follow up]
  • Signs of infection [Time frame: 3 and 12 months follow up]
  • occurrence of PJI [Time frame: up to 12 months]
  • Peri-operative and postoperative adverse events and device deficiencies. [Time frame: up to 12 months]

Eligibility criteria

Inclusion criteria

  • Informed Consent signed by the subject
  • Males and females aged over 18 years at time of surgery
  • Subjects who are scheduled to receive a conical collarless cementless revision hip arthroplasty, with or without revision of the acetabular cup
  • Subjects willing to comply with the pre- and post-operative evaluation schedule

Exclusion criteria

  • Subjects with one or more medical conditions identified as a contraindication defined by the labelling on any implants used in this study
  • Subjects with immune suppressive treatment for organ transplantation, or known allergy to MectaShield hydrogel constituents (Chitlac, Mannitol, Hydroxypropylmethylcellulose, Sodium phosphate dibasic)
  • Subjects presenting with progressive local or systemic infection at the time of surgery
  • Subjects whose prospects for a recovery to independent mobility would be compromised by known coexistent, medical problems
  • Subjects affected by concomitant spine, hip, ankle or contralateral knee pathologies that can affect walking capacity
  • Subjects unable to understand and take action
  • Subjects undergoing cementless revision hip arthroplasty in emergency interventions

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Allocation
Randomized
Model
Parallel assignment
Masking
Single blind
Primary purpose
Prevention

Study locations

Austria · 1 center
  • Orthopädisches Spital Speising GmbH — Vienna

Identifiers

NCT: NCT05679232 · P01.025.01

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗