Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0)
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: TAVR for BAV Using Down Sizing with the Evolut Pro platform, TAVR for BAV Using Traditional Sizing strategy with the Evolut Pro platform.
- Who it may be relevant to
- Registry conditions: Aortic Stenosis With Bicuspid Valve. Basic parameters: from 60 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- China
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Transcatheter Aortic Valve Replacement For Patients With Bicuspid Aortic Stenosis (Type 0) Using Down Sizing Strategy Compared With Standard Sizing Strategy (HANGZHOU Solution): A Prospective, Multicenter, Randomized Controlled Trial
Overview
To compare down sizing strategy versus annular sizing strategy technique (control group) in Type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding valves (SEVs): a randomized superiority trial
Detailed description
Transcatheter aortic valve replacement (TAVR) has emerged as a favorable alternative for severe symptomatic aortic stenosis (AS) patients of all surgical risk profiles. Patients with bicuspid aortic valve (BAV) underwent TAVR had similar 30-day mortality as well as stroke and new pacemaker implantation rates compared to tricuspid aortic valve (TAV) subjects, but carried higher risk of moderate/severe perivalvular leakage (PVL), conversion to surgery and device failure. Clinical experience in China suggests BAV and heavy calcium burden are more common among TAVR candidates than US/EU cohorts.
Morphological characteristics at supra-annular structure (from annulus to the level of sinotubular junction) are quite complex in BAV, especially concomitant with heavily calcified leaflets. From our previous single center clinical practice, "waist sign" above the annulus during balloon aortic valvuloplasty in TAVR was often observed in patients with bicuspid AS, suggesting that supra-annular structures are the most constrained portion of BAV anatomy where the prosthesis anchors and seals. Therefore, we developed a balloon based supra-annular sizing strategy for self-expanding valves implantation in BAV and the device failure rate as well as pacemaker implantation rates were relatively low as shown in previous cohort study. Several other studies have also achieved successful outcomes associated with device "down sizing" (using a device smaller than that recommended by annular sizing).
The aim of this study is to compare "down sizing"strategy (experimental group) versus annular sizing strategy (control group) in BAV patients undergoing TAVR with self-expanding valves.
Interventions
- Procedure TAVR for BAV Using Down Sizing with the Evolut Pro platform
Down sizing strategy in Type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement with self-expanding valves - Procedure TAVR for BAV Using Traditional Sizing strategy with the Evolut Pro platform
Traditional sizing strategy in Type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement with self-expanding valves
Primary outcome measures
- Composite endpoint of Clinical Event Rate of Device Success (VARC-3), Free of pacemaker implantation, and Free of new onset complete left bundle branch block at 1 month [Time frame: 1 month after index procedure]
Secondary outcome measures (4)
- New onset complete left bundle branch block [Time frame: 1 month after index procedure]
- Permanent pacemaker implantation [Time frame: 1 month after index procedure]
- Device success Rate [Time frame: 1 month after index procedure]
- More than (≥) moderate regurgitation [Time frame: 1 month after index procedure]
Eligibility criteria
Inclusion criteria
- Age ≥ 65 years;
- Age <65 years and age ≥ 60 years with high surgical risk after combing STS Risk Estimate (≥ 8%), Katz activities of Daily Living, major Organ System Dysfunction and Procedure-Specific Impediment;
- Severe, bicuspid aortic stenosis: Mean gradient ≥40 mmHg OR Maximal aortic valve velocity ≥4.0 m/sec OR Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2); if SVi <35mL/m2, low-dose dobutamine stress echocardiography is required;
- NYHA classification ≥ II;
- Type 0 (Sievers classification) by MDCT;
- Perimeter-derived annulus diameter ranges from 20.0 mm to 26.0 mm;
- Candidate for Transfemoral TAVR;
- The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board (IRB)/Ethics Committee (EC) of the respective clinical site.
Exclusion criteria
- Any contra-indication for Self-expanding bioprosthetic aortic valve deployment Leukopenia (WBC < 3000 cell/mL), acute anemia (Hgb < 9 g/dL), Thrombocytopenia (Plt< 50,000 cell/mL).
- Active sepsis, including active bacterial endocarditis with or without treatment;
- Evidence of an acute myocardial infarction ≤ 1 month (30 days) before the intended treatment \[(defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)\].
- Stroke or transient ischemic attack (TIA) within 3 months (90 days) of the procedure.
- Estimated life expectancy < 12 months (365 days) due to carcinomas, chronic liver disease, chronic renal disease or chronic end stage pulmonary disease.
- Any Emergent surgery required before TAVR procedure.
- A known hypersensitivity or contraindication to any of the following that cannot be adequately medicated:aspirin or heparin (HIT/HITTS) and bivalirudin; clopidogrel; Nitinol (titanium or nickel); contrast media
- Gastrointestinal (GI) bleeding that would preclude anticoagulation.
- Subject refuses a blood transfusion.
- Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits).
- Other medical, social, or psychological conditions that in the opinion of the investigator precludes the subject from appropriate consent or adherence to the protocol required follow-up exams.
- Currently participating in an investigational drug or another device study (excluding registries).
- Hypertrophic cardiomyopathy (HCM with myocardium more than 1.5cm without an identifiable cause) with obstruction (HOCM).
- Echocardiographic evidence of intracardiac mass, thrombus or vegetation.
- Severe mitral stenosis amenable to surgical replacement or repair.
- Aortic valve type cannot be determined (Sievers classification).
- Significant aortic disease, including marked tortuosity (hyperacute bend), aortic arch atheroma \[especially if thick (> 5 mm), protruding or ulcerated\] or narrowing (especially with calcification and surface irregularities) of the abdominal or thoracic aorta, severe"unfolding" and horizontal aorta(Annular Angulation>70°).
- Ascending aorta diameter > 50 mm.
- Aortic or iliofemoral vessel characteristics that would preclude safe placement of the introducer sheath.
- Patient is considered high risk for TAVR by CT corelab, including coronary obstruction, annular rupture and other severe TAVR-Related complications.
- Previous pacemaker implantation.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- Randomized
- Model
- Parallel assignment
- Masking
- Double blind
- Primary purpose
- Treatment
Study locations
China · 15 centers
- Fujian Provincial Hospital, Affiliated to Fuzhou University — Fuzhou
- Xiamen Cardiovascular Hospital Xiamen University — Xiamen
- Lanzhou University First Hospital — Lanzhou
- Nanfang Hospital of Southern Medical University — Guangzhou
- SUN YAT-SEN MEMORIAL HOSPITAL SUN YAT-SEN University — Guangzhou
- Yulin First People's Hospital — Yulin
- Zhengzhou Seventh People's Hospital — Zhengzhou
- The Second XIANGYA Hospital Of Central South University — Changsha
- … and 7 more centers
Publications
- Guo Y, Liu X, Li R, Ng S, Liu Q, Wang L, Hu P, Ren K, Jiang J, Fan J, He Y, Zhu Q, Lin X, Li H, Wang J. Comparison of downsizing strategy (HANGZHOU Solution) and standard annulus sizing strategy in type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement: Rationale and design of a randomized clinical trial. Am Heart J. 2024 Aug;274:65-74. doi: 10.1016/j.ahj.2024.0 PMID 38701961
Identifiers
NCT: NCT05511792 · SAHZU 2022-0327