Menu
Recruiting NCT05165537

Non-Invasive Monitoring Of Metabolite Levels Using Novel And Adapted MR Spectroscopy Techniques

No phase Interventional Magnetic Resonance Spectroscopy

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: NIMM_MRS.
Who it may be relevant to
Registry conditions: Magnetic Resonance Spectroscopy. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Switzerland
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

Evaluation of Novel and Adapted MR Spectroscopy and Metabolic Imaging Techniques for Non-invasive Monitoring of Metabolite Levels in Humans in Physiologic States of Everyday Life

Overview

This Swiss National Science Foundation (SNF) funded project and the linked European project aim * to improve magnetic resonance (MR) methods, specifically MR spectroscopy and metabolic imaging (making them more sensitive and accurate - also less dependent on motion), * to extend them (making previously unobservable metabolites visible) and also * to make them more stable (suitable for routine clinical use). Magnetic resonance spectroscopy (MRS) is closely related to the widely used magnetic resonance imaging (MRI). Both methods are based on the same physical effect and are performed on the same equipment. However, while MRI mainly images the anatomy inside the body, MRS gives us information about the metabolism of the tissue. The main goal of this study is to develop and improve methods of MRS to better measure the concentrations of endogenous substances without actual intervention. MRS methodology development is performed in 4 steps: 1. A new method is developed and optimized theoretically and in sample preparations (solutions of chemicals). 2. The new methodology is evaluated in single healthy volunteers and optimized step by step for the conditions of use in the human body. 3. The methodology in evaluated in small groups of healthy volunteers (measurement accuracy and range of variation in healthy volunteers). 4. Feasibility is studied in different situations with possibly different metabolic situations (e.g. awake versus asleep or before and after muscular exertion). For this purpose, about 100 subjects will be measured for different subprojects. Thus, among other things, one determines the measurement accuracy and also normal values in healthy subjects for the assessment of diseases in future studies.

Detailed description

Magnetic resonance imaging (MRI) and spectroscopy (MRS) provide non-invasive modalities to explore human morphology, function and metabolism. MRS methods are in widespread use in clinical research and to some degree in clinical applications. MRS methodology has been continuously extended for the last 30 years. All extensions employing novel MR pulse sequences (acquisition software), acquisition hardware capabilities of MRI scanners or post-processing methods have to be validated in theory, and in practice, where they are first tested in vitro and then in healthy subjects. The proposed project is based on a SNF project and a Horizon 2020 project of the sponsor-investigator, where multiple methodological extensions of MRS sequences are implemented for improved measurements of metabolite levels, characteristics and maps.

The intended study uses MRI-scanners which have a Conformité Européenne (CE) label for diagnostic use. The manufacturer of the MR scanner provides a "research-license mode" with the very same hardware; however, since the flexibility of this mode of operation makes a CE process prohibitively long and complex, no CE label was aimed at for the research-license mode.

The methodological developments within the proposed study aim at novel or improved sequences, which have the potential to observe previously undetectable metabolites and to evaluate metabolite changes as function of time-of-day or previous exercise. The sequences are applied in investigations of healthy adult subjects in everyday physiological situations to document the potential of the novel methods in terms of accuracy, precision, robustness. Without such investigations on healthy subjects the methodological advances cannot be verified in a valid situation and thus not ported to more specific research trials or clinical applications.

Interventions

  • Device NIMM_MRS
    evaluation of new MRS methods

Primary outcome measures

  • healthy-cohort signal intensity characteristics for metabolites of interest (MOI) [Time frame: 2 months]
Secondary outcome measures (1)
  • healthy-cohort signal resolution and uncertainty characteristics for metabolites of interest (MOI) [Time frame: 2 months]

Eligibility criteria

Inclusion criteria

  • signed informed consent
  • healthy (no neuronal or metabolic diseases as stated by the study participant)
  • able to lie still in the MR scanner for at least one hour

Exclusion criteria

  • <18 yrs of age
  • pregnancy or current state of lactation
  • active implants
  • passive ferromagnetic implants
  • passive non-ferromagnetic metallic implants > 4 cm inside a region covered by the active radio-frequency (RF) coils
  • large tattoos inside a region covered by the active RF coils
  • known or suspected non-compliance,
  • under-weight (<35 kg body weight)

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: Yes

Study design

Allocation
N/A
Model
Single group
Masking
Open label
Primary purpose
Basic science

Study locations

Switzerland · 1 center
  • Translational Imaging Center — Bern

Identifiers

NCT: NCT05165537 · NIMM_MRS

Primary sources (government registries)