Characterization of an Optically Pumped Magnetometer (OPM) Magnetoencephalography (MEG) Array
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: SQUID MEG, OPM MEG.
- Who it may be relevant to
- Registry conditions: Normal Physiology. Basic parameters: 18 years — 65 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- United States
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Overview
Background: Brain activity produces magnetic fields. These fields can be measured outside the head. Existing technology, called MEG, measures these fields. Researchers are testing a new type of magnetic field sensor called OPM. They hope it can help pinpoint with very high accuracy where brain activity is generated. Objective: To develop and test a new type of sensor for measuring the magnetic fields produced by brain activity. Eligibility: Healthy people ages 18-65 who had a magnetic resonance imaging (MRI) scan under protocol 17-M-0181. Design: Participants may be asked to complete sessions on both the traditional MEG instrument and the OPM array. For the MEG, 3 small coils will be placed on the participant s face with tape. Their head will be positioned inside the MEG device. For the OPM, sensors are housed in a 3d printed array. The sensors will be attached to a cap placed on the participant s head. For both scans, participants will be seated in a chair inside a magnetically shielded room. They may complete several tasks. In one task, plastic cells will be placed on their fingers. Puffs of air will be sent to these cells, which will stimulate the sense of touch. Other tasks may include the following stimuli: visual (such as checkerboards), auditory (such as beeps and tones), or language (words and letters). Researchers may also obtain recordings while they stimulate the nerve in the participant s forearm using electrical current in small electrodes. Participation is expected to last for 1 day. Additional optional scans may be offered for up to 1 year....
Detailed description
Study Description:
This protocol is a technical development protocol to characterize an optically pumped magnetometer (OPM) array used for measuring magnetic brain signals. We hypothesize that with our OPM arrays, we can achieve similar or better spatial resolution to that of a conventional MEG system.
Objectives:
Primary Objective 1: To fully characterize the performance of an OPM MEG array.
Primary Objective 2: To demonstrate that the OPM system can produce somatotopic maps accurately differentiating receptive fields of each finger. If successful, we will additionally determine if the system can differentiate receptive fields of each phalanx.
Endpoints:
Primary Endpoint: OPM array characterization parameters including signal to noise, sensitivity, bandwidth, and spatial
resolution, and comparison to similar parameters acquired on a standard SQID system.
Secondary Endpoint: Somatotopic representations of the digits of the hand
Interventions
- Device SQUID MEG
MEG recordings acquired on a standard whole brain SQUID MEG system. Stimuli will be used, including auditory, visual, or somatosensory stimuli. Language stimuli and median nerve stimulation may also be used. - Device OPM MEG
MEG recordings acquired on an investigational OPM MEG system. Stimuli will be used, including auditory, visual, or somatosensory stimuli. Language stimuli and median nerve stimulation may also be used.
Primary outcome measures
- array characterization metrics [Time frame: throughout protocol]
Secondary outcome measures (1)
- Somatotopic representations [Time frame: throughout protocol]
Eligibility criteria
- INCLUSION CRITERIA:
In order to be eligible to participate in this study, an individual must meet all of the following criteria:
- Provision of signed and dated informed consent form
- Stated willingness to comply with all study procedures and availability for the duration of the study
- Male or female, aged 18-65
- In good general health as evaluated according to protocol 17-M-0181
- Completed a magnetic resonance imaging (MRI) scan under 17-M-0181
Exclusion criteria
An individual who meets any of the following criteria will be excluded from participation in this study:
- Participants excluded from 17-M-0181 will be excluded from this protocol
- Metal in the body which would cause artifacts on MEG recordings
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: Yes
Study design
- Allocation
- N/A
- Model
- Single group
- Masking
- Open label
- Primary purpose
- Device feasibility
Study locations
United States · 1 center
- National Institutes of Health Clinical Center — Bethesda
Identifiers
NCT: NCT04950309 · 210018 · 21-M-0018