Menu
Recruiting NCT04801654

GMK Sphere TiNb Total Knee Arthroplasty PMS Study

Observational Total Knee Arthroplasty

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
The protocol lists: blood sample.
Who it may be relevant to
Registry conditions: Total Knee Arthroplasty. Basic parameters: from 18 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
Italy
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Official title

A Monocentric, Prospective Clinical Survey on Long Term Performance of GMK Sphere Total Knee Arthroplasty

Overview

Total knee arthroplasty (TKA) is one of the success stories of modern surgery, providing high patient satisfaction outcomes. Total knee prostheses are generally composed by a femoral component articulating on a polyethylene insert and a tibial tray. Recently there has been particular attention on the component material; traditionally femoral components are made of cobalt alloys while tibial baseplates are made, in the great majority of cases, of metallic materials, but also polyethylene versions are available. There has been a degree of acceptance in some countries that metal related pathology may exist as demonstrated by the Australian Arthroplasty register where metal hypersensitivity was reported as the fifth most common cause for revision hip arthroplasty 2012 report, making up for 5.9% of all revisions. The wording was subsequently changed from "metal sensitivity" to "metal related pathology" in the 2014 report with 0.5% of all revision total hip arthroplasties (THA) associated with this term. The same change in terminology was used for TKA with metal sensitivity as a cause for revision in 1.3% of revisions in 2012 and in 2014, 1.8% of revision TKAs attributed to "metal related pathology" . The overall revision rate was 3.45% after 10 years in 396.472 TKAs, suggesting a revision rate of 0.06-0.32% secondary to metal or cement allergies. Up to today there is no question that metallic implants may generate wear debris that cause local reactions. This local reaction is not dose related nor predictable and therefore not purely due to the toxic effect of the debris but possibly due to an immunological host process. Hypersensitivity to metal undoubtedly exists but it cannot be stated at the moment to be an allergic reaction. To prevent issues arising due to metal related pathology, alternative solutions to conventional chrome cobalt material have been proposed, for example ceramic component or implant coating. In particular, TiNbN coating has been proposed by most companies thanks to its excellent biological properties. Preclinical studies have showed a high scratch resistance and low coefficient of friction, more resistance to fretting corrosion, reduction of wear, lower ion release rates and low fatigue cycle, as described in the review of Hove. Clinically, cohort of studies of TiN-coated implants showed an overall survival exceeding 90% with a follow-up of 15 to 77 months and good clinical outcomes. No reports of adverse effects related to TiN coating of CoCrMo knee implants have been showed. There are few studies that compared TiN-coated implants with the same uncoated version. Thienpont, comparing TiN-coated and uncoated CoCrMo implants, showed similar clinical and radiological outcomes at short-term follow up in both patients groups . Overall we can conclude that in literature no adverse events have been reported concerning the TiNbN coating and in particular it has been showed that the coating doesn't not affect the performance of the device if compared with the same uncoated version. The aim of this study is to evaluate the long term clinical and radiological performance of GMK Sphere total knee component, coated version.

Interventions

  • Diagnostic test blood sample
    preoperative and at 6 months and 1 year follow-up after the surgery the patients will take a blood sample

Primary outcome measures

  • Long term performance [Time frame: 10 years]
Secondary outcome measures (6)
  • Clinical performance [Time frame: 6 months, 1, 5 and 10 years after surgery]
  • Radiological performance [Time frame: (1, 5 and 10 years after surgery]
  • Retropatellar pain [Time frame: 6 months and 1, 5 and 10 years after surgery]
  • Ion release rate [Time frame: preoperative, 6 months and 1 year visits]
  • Activity level after surgery [Time frame: 6 months and 1year after surgery]
  • Rate of complications [Time frame: up to 10 years after surgery]

Eligibility criteria

Inclusion criteria

  • Those older than 18 years old at the surgery time
  • those suitable to undergo to a primary total knee arthroplasty for whom the GMK Sphere TiNb coated device will be implanted (according to the label indication/contraindications)
  • Patients who are willing and able to provide written informed consent for participation in the study. Written informed consent must be obtained prior to patient's surgery

Exclusion criteria

  • Those patients with metal implants containing Co, Cr and / or Ni
  • Those patients who have had environmental or occupational exposure to toxic metals such as Co, Cr and / or Ni (solvents, industrial paints, welders)
  • Those whose mental conditions may compromise their ability to provide informed consent to study participation, ability to complete questionnaires or complete 10-year follow-ups
  • Those unable to give their consent to participate in the study or who do not want to participate
  • Any condition not mentioned in inclusion criteria.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: No

Study design

Observational model
Cohort

Study locations

Italy · 1 center
  • IRCCS Istituto Ortopedico Galeazzi di Milano Sede di via Monreale18 (Istituto Clinico San — Milan

Identifiers

NCT: NCT04801654 · P.02.01.427

Primary sources (government registries)