PARTNER 3 Trial - Aortic Valve-in-Valve
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: Edwards SAPIEN 3/SAPIEN 3 Ultra THV.
- Who it may be relevant to
- Registry conditions: Aortic Stenosis, Aortic Stenosis, Severe. Basic parameters: No limits · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- United States, Canada
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
A Prospective, Single-Arm, Multicenter Study to Investigate the Safety and Effectiveness of SAPIEN 3/SAPIEN 3 Ultra Transcatheter Heart Valve Implantation in Patients With a Failing Aortic Bioprosthetic Valve
Overview
This study will assess the safety and effectiveness of the SAPIEN 3/SAPIEN 3 Ultra transcatheter heart valve (THV) in patients with a failing aortic bioprosthetic valve.
Detailed description
This is a prospective, single-arm, multicenter study.
Interventions
- Device Edwards SAPIEN 3/SAPIEN 3 Ultra THV
Edwards SAPIEN 3/SAPIEN 3 Ultra THV system with the associated delivery systems.
Primary outcome measures
- Safety and Effectiveness - Non-hierarchical composite of all-cause mortality and stroke [Time frame: 1 year]
Secondary outcome measures (5)
- Mean gradient [Time frame: 30 days]
- Peak gradient [Time frame: 30 days]
- Kansas City Cardiomyopathy Questionnaire (KCCQ) [Time frame: 30 days]
- New York Heart Association (NYHA) Classification [Time frame: 30 days]
- Six-Minute Walk Test (6MWT) [Time frame: 30 days]
Eligibility criteria
Inclusion criteria
- Failing surgical or transcatheter bioprosthetic valve in the aortic position demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency.
- Bioprosthetic valve with a true internal diameter (True ID) of 18.5 mm to 28.5 mm.
- NYHA Functional Class ≥ II.
- Heart Team agrees the patient is low to intermediate risk.
- Heart Team agrees valve implantation will likely benefit the patient.
- The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.
Exclusion criteria
- Surgical or transcatheter valve in the mitral position (mitral rings are not an exclusion)
- Severe regurgitation (> 3+) or stenosis of any other valve
- Failing valve has moderate or severe paravalvular regurgitation
- Failing valve is unstable, rocking, or not structurally intact
- Increased risk of coronary obstruction by prosthetic leaflets of the failing valve.
- Increased risk of embolization of THV
- Known bioprosthetic valve with residual mean gradient > 20 mmHg at the end of the index procedure for implantation of the original valve
- Iliofemoral vessel characteristics that would preclude safe placement of the introducer sheath (Transfemoral)
- Anatomical characteristics that would preclude safe access to the ascending aorta (Transaortic)
- Anatomical characteristics that would preclude safe access to the apex (Transapical)
- Evidence of an acute myocardial infarction ≤ 30 days before enrollment
- Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days prior to the index procedure. Implantation of a permanent pacemaker or implantable cardioverter defibrillator is not considered an exclusion.
- Patients with planned concomitant surgical or transcatheter ablation for Atrial Fibrillation
- Leukopenia, anemia, thrombocytopenia, history of bleeding diathesis or coagulopathy or hypercoagulable states
- Untreated clinically significant coronary artery disease requiring revascularization
- Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation, or mechanical heart assistance within 30 days of enrollment
- Emergency interventional/surgical procedures within 30 days prior to the procedure
- Any planned surgical, percutaneous coronary, or peripheral procedure to be performed within the 30-day follow-up from the procedure
- Hypertrophic cardiomyopathy with obstruction
- LVEF < 30%
- Cardiac imaging evidence of intracardiac mass, thrombus, or vegetation
- Inability to tolerate or condition precluding treatment with antithrombotic/anticoagulation therapy during or after the valve implant procedure
- Absolute contraindications or allergy to iodinated contrast that cannot be adequately treated with premedication
- Stroke or transient ischemic attack within 90 days of enrollment
- Symptomatic carotid or vertebral artery disease or successful treatment of carotid stenosis within 30 days of enrollment
- Renal insufficiency and/or renal replacement therapy at the time of screening
- Active bacterial endocarditis within 180 days of the procedure
- Patient refuses blood products
- Estimated life expectancy < 24 months
- Positive urine or serum pregnancy test in female subjects of childbearing potential
- Currently participating in an investigational drug or another device study
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- N/A
- Model
- Single group
- Masking
- Open label
- Primary purpose
- Treatment
Study locations
United States · 50 centers
- Banner University Medical Center — Phoenix
- University of California Los Angeles — Los Angeles
- Sutter Medical Center — Sacramento
- Kaiser Permanente San Francisco — San Francisco
- Stanford University Medical Center — Stanford
- UC Health Northern Colorado/Medical Center of the Rockies — Loveland
- Hartford Hospital — Hartford
- JFK Medical Center/ Atlantic Clinical Research Collaborative — Atlantis
- … and 42 more centers
Canada · 1 center
- St. Paul's Hospital, Providence Health Care — Vancouver
Identifiers
NCT: NCT03003299 · 2015-08 AVIV