Menu
Recruiting NCT01130545

Imaging Techniques in MRI

Observational Cardiac Risk Factors Healthy Healthy Volunteers

For patients and families

In plain language

An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.

What is being studied
This is an observational study: the protocol does not assign a study treatment.
Who it may be relevant to
Registry conditions: Cardiac Risk Factors, Healthy, Healthy Volunteers. Basic parameters: 18 years — 100 years · All.
What needs checking
Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
Where it takes place
United States
Next step
Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →

Overview

Background: \- Magnetic resonance imaging (MRI) scans must be performed according to specified sets of parameters that provide optimal images of each organ and each area of the body. These scanning parameters are often specific to the institution or organization at which they are employed, and may also depend on the manufacturer of the MRI scanning equipment. Because MRI scanning equipment is always being updated and upgraded, researchers are interested in developing new and optimized scanning parameters for MRI scans. Objectives: \- To improve current methods and develop new techniques for magnetic resonance imaging. Eligibility: * Individuals 18 years of age and older who are either volunteers or current NIH protocol participants. * Participants must not have any medical history factors (e.g., extreme claustrophobia, history of metal implants) that would prevent them from receiving MRI scans. Design: * Participants will have at least one MRI scan that will last from 20 minutes to 2 hours (most scans will last between 45 and 90 minutes). The total time commitment for most visits will be approximately 4 hours from start to finish. * Some MRI techniques require standard monitoring equipment or specific procedures during the scanning, such as an electrocardiogram. * Participants will have blood samples taken at the time of the scan. Some MRI studies will require the use of a contrast agent that will be administered during the scan. * Volunteers may be asked to return for additional MRI scans over the course of a few years. Follow-up scans may be done on the same part of the body or on different parts of the body. No more than one MRI scan will be performed in any 4-week period for this protocol.

Detailed description

Magnetic Resonance (MR) Imaging performed on volunteers will be used to develop and optimize techniques useful in the advancement of MRI technology.

Primary outcome measures

  • To refine current methodology and develop new techniques for MRI [Time frame: End of study]

Eligibility criteria

  • INCLUSION CRITERIA:

A. Volunteer individuals

B. Lab Eligibility parameters (for contrast scans within 4 weeks of gadolinium injection):

C. Creatinine below upper normal limit

D. eGFR >= 60 mL/min/1.73m2

E. Age >= 60 or history of renal disease: test GFR within 1 week prior to contrast

F. Willing to travel to the NIH for follow-up visits.

G. 18 years old

H. Able to understand and sign informed consent

I. No MRI scan with gadolinium injection in the last 6 months under this protocol.

Exclusion criteria

A. Implanted metal clips or wires of the type which may concentrate radiofrequency fields or cause tissue damages from twisting in a Magnetic field. Examples:

  • Aneurysm clip, implanted neural stimulator,
  • Implanted cardiac pacemaker, defibrillator, or certain other implanted electrical or metallic devices,
  • Cochlear implant, ocular foreign body (metal shavings),
  • Any implanted device (pumps, infusion devices, etc.),
  • Shrapnel injuries,
  • History of metal in head or eyes or other parts of the body.

B. Pregnant women

C. Paralyzed hemidiaphragm

D. Over 500 lbs and/or a body circumference that prevents the study subject from laying flat in the scanner

E. Surgery of uncertain type

F. Untreatable claustrophobia otherwise requiring anesthesia.

G. Any contraindications that the Physician identifies from the subject, MRI Safety Questionnaire, and/or History and Physical.

EXCLUSION FOR PARTICIPANTS FOR GADOLINIUM CONTRAST:

(Inclusive of the above exclusion criteria):

A. Allergy to gadolinium for scans using contrast; will be eligible for non-contrast scans.

B. Acute renal failure, renal transplant, dialysis and renal failure individuals (eGFR <60 mL/min/1.73m2 and/or clinically diagnosed).

C. Individuals with a history of liver transplant or severe liver disease.

D. Lactating women

E. Individuals with hemoglobinopathies or severe asthma.

F. Patient preference to not undergo intravenous line placement and/or receive gadolinium contrast. Contrast administration is optional and participants may still undergo a non-contrast study.

G. GBCA with an MRI scan in the last 6 months. This includes scan performed with GBCA at any outside institution and / or at the clinical center .In addition, they cannot have reached their maximum of 4 GBCA imaging studies under this protocol. They will be excluded from having a contrast enhanced MRI, but will not be excluded from the protocol for non-contrast MRI studies.

Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.

Healthy volunteers: Yes

Study design

Observational model
Other

Study locations

United States · 1 center
  • National Institutes of Health Clinical Center — Bethesda

Publications

  • Mattay VS, Weinberger DR, Barrios FA, Sobering GS, Kotrla KJ, van Gelderen P, Duyn JH, Sexton RH, Moonen CT, Frank JA. Brain mapping with functional MR imaging: comparison of gradient-echo--based exogenous and endogenous contrast techniques. Radiology. 1995 Mar;194(3):687-91. doi: 10.1148/radiology.194.3.7862963. PMID 7862963
  • Perez-Rodriguez J, Lai S, Ehst BD, Fine DM, Bluemke DA. Nephrogenic systemic fibrosis: incidence, associations, and effect of risk factor assessment--report of 33 cases. Radiology. 2009 Feb;250(2):371-7. doi: 10.1148/radiol.2502080498. PMID 19188312
  • Frank JA, Mattay VS, Duyn J, Sobering G, Barrios FA, Zigun J, Sexton R, Kwok P, Woo J, Moonen C, et al. Measurement of relative cerebral blood volume changes with visual stimulation by 'double-dose' gadopentetate-dimeglumine-enhanced dynamic magnetic resonance imaging. Invest Radiol. 1994 Jun;29 Suppl 2:S157-60. doi: 10.1097/00004424-199406001-00052. No abstract available. PMID 7928216
  • Ahlman MA, Raman FS, Penzak SR, Pang J, Fan Z, Liu S, Gai N, Li D, Bluemke DA. Part 1 - Coronary angiography with gadofosveset trisodium: a prospective feasibility study evaluating injection techniques for steady-state imaging. BMC Cardiovasc Disord. 2015 Dec 22;15:177. doi: 10.1186/s12872-015-0176-0. PMID 26695065
  • Raman FS, Nacif MS, Cater G, Gai N, Jones J, Li D, Sibley CT, Liu S, Bluemke DA. 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium. Int J Cardiovasc Imaging. 2013 Jun;29(5):1085-94. doi: 10.1007/s10554-013-0192-z. Epub 2013 Mar 21. PMID 23515949

Identifiers

NCT: NCT01130545 · 100115 · 10-CC-0115

Primary sources (government registries)

View this study on ClinicalTrials.gov ↗