Evaluation of an Advanced Lower Extremity Neuroprostheses
For patients and families
In plain language
An automatic summary of structured registry data. It is an orientation aid, not a substitute for the official protocol or a physician assessment.
- What is being studied
- The protocol lists: IST (Implanted Stimulator-Telemeter).
- Who it may be relevant to
- Registry conditions: Spinal Cord Injuries, Stroke, Paralysis, Tetraplegia. Basic parameters: 21 years — 75 years · All.
- What needs checking
- Age, condition and sex are only basic indicators. Prior treatment, laboratory values and other mandatory requirements appear in the eligibility criteria below.
- Where it takes place
- United States
- Next step
- Save the trial, show it to the treating physician, and confirm current recruitment with the study center. Costs, documents and travel →
Unsure about the terms? Read our patient guide →
Official title
Evaluation of Advanced Lower Extremity Neuroprostheses
Overview
The purpose of this study is to evaluate a surgically implanted functional electrical stimulation (FES) system to facilitate exercise, standing, stepping and/or balance in people with various degrees of paralysis.
Detailed description
Protocol Outline: Patents undergo surgery in which electrodes are implanted into muscles of the trunk and legs. Electrode leads are connected to an stimulator/telemeter. Following implantation, patients undergo training in standing, transfers and other advanced mobility skills using the functional electrical stimulation system. A prescribed course of exercise, functional training and rehabilitation with the implanted stimulation system, followed by laboratory assessments of strength, balance and functional abilities with and without the system, as well as the technical performance of the implanted components. Home-based training follows prior to discharge for home use of the system.
Patients are followed at 6 and 12 months after discharge and then annually thereafter.
Interventions
- Device IST (Implanted Stimulator-Telemeter)
Pre-surgical exercise with surface electrical stimulation, surgery including electrode and IST- implanted pulse generator insertion, exercise and physical therapy with the implanted system, functional training and laboratory assessment of clinical and technical performance.
Primary outcome measures
- Device reliability and technical performance measuring changes in standing duration from baseline at discharge to 12 months after discharge [Time frame: Change from immediately after intervention and 1 year after intervention]
- Device reliability and technical performance measuring changes in standing loads from baseline at discharge to 12 months after discharge [Time frame: Change from immediately after intervention and 1 year after intervention]
- Device reliability and technical performance measuring changes in walking distance from baseline at discharge to 12 months after discharge [Time frame: Change from immediately after intervention and 1 year after intervention]
- Device reliability and technical performance measuring changes in walking duration from baseline at discharge to 12 months after discharge [Time frame: Change from immediately after intervention and 1 year after intervention]
Secondary outcome measures (1)
- Device operability measuring changes in functional activities of daily living from baseline at discharge and 12 months after discharge [Time frame: Change from immediately after intervention and 1 year after intervention]
Eligibility criteria
Phase I Inclusion Criteria
- Skeletal maturity and ability to sign informed consent (>18 years)
- Non-ventilator dependent paralysis resulting from injuries such as: mid cervical/thoracic (C4 or below) spinal cord injuries, poststroke hemiparesis, TBI, or MS, affecting the trunk and/or lower limbs
- Innervated and excitable lower extremity and trunk musculature
- Adequate social support and stability
- Willingness to comply with follow-up procedures
Phase I Exclusion Criteria
- Non-English speaking
- Females who are pregnant
- Current pressure injuries that would be exacerbated by study activities
- Severe contractures or uncontrolled spasticity of any major joint of the upper or lower extremities that results in a fixed deformity that would interfere with study activities
- History of spontaneous fractures or other evidence of excessively low bone density
- History of vestibular dysfunction, balance problems, or spontaneous falls
- Acute and or/untreated orthopedic problems that would prevent a participant from weight bearing or exercising such as a dislocation or fracture.
Criteria are shown verbatim from the registry (in English). Final eligibility is always assessed by the study center.
Healthy volunteers: No
Study design
- Allocation
- N/A
- Model
- Single group
- Masking
- Open label
- Primary purpose
- Device feasibility
Study locations
United States · 2 centers
- Louis Stokes Cleveland VA Medical Center — Cleveland
- MetroHealth System — Cleveland
Publications
- Dutta A, Kobetic R, Triolo RJ. Ambulation after incomplete spinal cord injury with electromyogram-triggered functional electrical stimulation. Conf Proc IEEE Eng Med Biol Soc. 2006;2006:5408-11. doi: 10.1109/IEMBS.2006.259257. PMID 17946304
- Uhlir JP, Triolo RJ, Davis JA Jr, Bieri C. Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury. IEEE Trans Neural Syst Rehabil Eng. 2004 Jun;12(2):279-87. doi: 10.1109/TNSRE.2004.827224. PMID 15218941
- Bogie KM, Triolo RJ. Effects of regular use of neuromuscular electrical stimulation on tissue health. J Rehabil Res Dev. 2003 Nov-Dec;40(6):469-75. doi: 10.1682/jrrd.2003.11.0469. PMID 15077659
- Agarwal S, Triolo RJ, Kobetic R, Miller M, Bieri C, Kukke S, Rohde L, Davis JA Jr. Long-term user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury. J Rehabil Res Dev. 2003 May-Jun;40(3):241-52. PMID 14582528
- Davis JA Jr, Triolo RJ, Uhlir J, Bieri C, Rohde L, Lissy D, Kukke S. Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand? J Rehabil Res Dev. 2001 Nov-Dec;38(6):609-17. PMID 11767968
- Fisher LE, Miller ME, Nogan SJ, Davis JA, Anderson JS, Murray LM, Tyler DJ, Triolo RJ. Preliminary evaluation of a neural prosthesis for standing after spinal cord injury with four contact nerve-cuff electrodes for quadriceps stimulation. Conf Proc IEEE Eng Med Biol Soc. 2006;2006:3592-5. doi: 10.1109/IEMBS.2006.260833. PMID 17947042
- Mushahwar VK, Jacobs PL, Normann RA, Triolo RJ, Kleitman N. New functional electrical stimulation approaches to standing and walking. J Neural Eng. 2007 Sep;4(3):S181-97. doi: 10.1088/1741-2560/4/3/S05. Epub 2007 Aug 22. PMID 17873417
- Triolo RJ, Bailey SN, Foglyano KM, Kobetic R, Lombardo LM, Miller ME, Pinault G. Long-Term Performance and User Satisfaction With Implanted Neuroprostheses for Upright Mobility After Paraplegia: 2- to 14-Year Follow-Up. Arch Phys Med Rehabil. 2018 Feb;99(2):289-298. doi: 10.1016/j.apmr.2017.08.470. Epub 2017 Sep 9. PMID 28899825
Identifiers
NCT: NCT00623389 · EB-001889